SCLK
DIN
Command
Byte
Command
Byte
t
(1)
SCLKDLY
SBAS418I – SEPTEMBER 2007 – REVISED MARCH 2015
10 Commands
The commands listed in
control the
In Read Data Continuous mode, the ADS1282 places
operation of the ADS1282. Most commands are
conversion data on the DOUT pin as SCLK is
stand-alone (that is, 1 byte in length); the register
applied. As a consequence of the potential conflict of
reads and writes require a second command byte in
conversion data on DOUT and data placed on DOUT
addition to the actual data bytes.
resulting from a register or Read Data By Command
operation, it is necessary to send a STOP Read Data
A delay of 24 f
CLK
cycles between commands and
Continuous command before Register or Data Read
between bytes within a command is required, starting
By Command. The STOP Read Data Continuous
from the last SCLK rising edge of one command to
command disables the direct output of conversion
the first SCLK rising edge of the following command.
data on the DOUT pin.
This delay is shown in
.
(1)
t
SCLKDLY
= 24/f
CLK
(min).
Figure 61. Consecutive Commands
Table 20. Command Descriptions
COMMAND
TYPE
DESCRIPTION
1st COMMAND BYTE
(1) (2)
2nd COMMAND BYTE
(3)
WAKEUP
Control
Wake-up from Standby mode
0000 000X (00h or 01h)
STANDBY
Control
Enter Standby mode
0000 001X (02h or 03h)
SYNC
Control
Synchronize the A/D conversion
0000 010X (04h or 5h)
RESET
Control
Reset registers to default values
0000 011X (06h or 07h)
RDATAC
Control
Read data continuous
0001 0000 (10h)
SDATAC
Control
Stop read data continuous
0001 0001 (11h)
RDATA
Data
Read data by command
(4)
0001 0010 (12h)
RREG
Register
Read
nnnnn
register(s) at address
rrrrr
(4)
001
r rrrr
(20h + 000
r rrrr
)
000
n nnnn
(00h +
n nnnn
)
WREG
Register
Write
nnnnn
register(s) at address
rrrrr
010
r rrrr
(40h + 000
r rrrr
)
000
n nnnn
(00h +
n nnnn
)
OFSCAL
Calibration
Offset calibration
0110 0000 (60h)
GANCAL
Calibration
Gain calibration
0110 0001 (61h)
(1)
X = don't care.
(2)
rrrrr = starting address for register read and write commands.
(3)
nnnnn = number of registers to be read/written – 1. For example, to read/write three registers, set
nnnnn
= 2 (00010).
(4)
Required to cancel Read Data Continuous mode before sending a command.
32
Copyright © 2007–2015, Texas Instruments Incorporated