5.6  KONFORT 720R

The 

KONFORT 720R

 charging station is the advanced version of the 

710R

charging station.

KONFORT 720R

 can operate on cars, trucks, and tractors.

MAIN FEATURES

R134a or R1234yf
compatible

Graphic LED display
240x128 COG 4.8"

DATABASE management
and services carried out via
SD CARD

Rotating pressure gauge
assembly-display (Germany
not included)

12 kg tank

Double stage vacuum pump

High efficiency refrigerant
recovery (over 95%)

Automatic oil injection (timed
operation)

2 manual (turn wheel) valves
for AC service hoses

Band heater

Operating mode:

DATABASE

CUSTOMIZED
SERVICE

MY DATABASE

Multilingual coverage of
the software

Service hoses automatic
length offset

Automatic maintenance
warning

Simplified maintenance

Incondensable gases
automatic drain
management

28

Summary of Contents for Konfort 700R Series

Page 1: ...ENGLISH 7 en...

Page 2: ...2...

Page 3: ...isoning Hazard 12 1 3 General User and Maintenance Warnings 12 2 KONFORT 700R SERIES USER SAFETY 13 2 1 Glossary 13 2 2 General Rules 14 2 3 Operator Safety 14 2 4 Device Safety 14 2 4 1 Safety Device...

Page 4: ...e View 34 6 3 Rear view 35 6 3 1 Containers 35 6 4 Left Side View 36 7 DESCRIPTION OF KONFORT 705R 705R OFF ROAD 707R 710R 710L 712R 37 7 1 Front view 37 7 1 1 Control panel display and top panel 39 7...

Page 5: ...to Use the Software 57 11 5 Printer 58 12 STOP 59 12 1 Normal Stop 59 12 2 Stopping the Equipment for Long Periods 59 13 UPDATING 60 14 MAINTENANCE 62 14 1 Ordinary Maintenance 62 14 1 1 Dryer Filter...

Page 6: ...18 KONFORT 710R 710L 712R TECHNICAL FEATURES 75 19 KONFORT 705R 705R OFF ROAD 707R 710R 710L TECHNICAL FEATURES 77 20 FLOW DIAGRAMS 79 21 LEGAL NOTICES 86 6...

Page 7: ...RT 700R RECHARGING AND MAINTENANCE STATIONS TECHNICAL MANUAL REVIEW OF THE MANUAL This document is review 12 of the technical manual for the KONFORT Series 700R charging stations Issue date 18 03 2019...

Page 8: ...ded to offer technical training of any kind and technicians will therefore carry out any interventions under their own responsibility and will be accountable for any damage or personal injury caused b...

Page 9: ...g in environment which is suitable for the operations that must be carried out The operator must report any faults or potentially hazardous situation in connection with the workplace or the device The...

Page 10: ...re working on is still hot This will avoid the fan from becoming activated unexpectedly even when the engine is off Do not wear ties loose clothes wrist jewellery or watches when working on a vehicle...

Page 11: ...r the openings of the batteries with a wet cloth in order to stifle the explosive gases before proceeding in testing or recharging Avoid causing sparks when connecting cables to the battery 1 2 7 Nois...

Page 12: ...eral User and Maintenance Warnings When using the device or carrying out scheduled maintenance eg fuse replacement on the device carefully follow the information provided below Do not remove or damage...

Page 13: ...he A C system in order to restore the correct quantity recommended by the manufacturer Operator qualified individual in charge of servicing air conditioning systems using the KONFORT 700R series recha...

Page 14: ...equired The operator is required to wear adequate safety glasses and gloves that prevent direct contact with the refrigerants The equipment has been designed to be steady both when being moved and onc...

Page 15: ...ar open flames sparks hot surfaces the refrigerant decomposes at high temperatures letting off toxic chemical substances that are harmful to people and the environment Do not expose the device to dire...

Page 16: ...he safety sheet of this refrigerant in order to store it correctly 2 6 Workplace Safety The device is designed to work at a maximum altitude of 1000 m above sea level with an operating temperature bet...

Page 17: ...on levels both in the refrigerant and in the oil If the history of the system is not known the refrigerant recovered must at least be recycled before it is reused When the contamination level is not k...

Page 18: ...ollowing directives 2014 68 EU 2014 30 EU 2006 42 EC 2014 35 EU 2011 65 EU A complete copy of the Declaration of Conformity can be obtained at Texa S p A Via 1 Maggio 9 31050 Monastier di Treviso TV I...

Page 19: ...KCC 19 en...

Page 20: ...and only prompt you with compatible TEXA devices This does not exclude the presence of other sources of communication or disturbance THE EFFICIENCY AND THE QUALITY OF BLUETOOTH WiFi AND 3G 4G COMMUNI...

Page 21: ...ore the data of each service carried out The database update can be performed through the SD CARD The 700R Series includes the following models 705R 705R OFF ROAD 707R 710R 710L 712R 720R 760R 760R BU...

Page 22: ...t available for these charging stations The charging stations that work with the R1234yf gas only are 707R The 780R BI GAS recharging stations are designed and already set up to operate with both refr...

Page 23: ...gement and services carried out via SD CARD Pressure gauge unit 10 kg tank Single stage vacuum pump High efficiency refrigerant recovery over 95 Automatic oil injection timed operation 2 manual turn w...

Page 24: ...hic LED display 240x128 COG 4 8 DATABASE management and services carried out via SD CARD Pressure gauge unit 10 kg tank Scale lock Single stage vacuum pump High efficiency refrigerant recovery over 95...

Page 25: ...ment and services carried out via SD CARD Pressure gauge unit 10 kg tank Single stage vacuum pump High efficiency refrigerant recovery over 95 Automatic oil injection timed operation Full automatic In...

Page 26: ...anagement and services carried out via SD CARD Pressure gauge unit Tank 710R 10 kg 710L 20 kg Double stage vacuum pump High efficiency refrigerant recovery over 95 Automatic oil injection timed operat...

Page 27: ...via SD CARD 10 kg tank Double stage vacuum pump High efficiency refrigerant recovery over 95 High precision automatic oil drain management Automatic oil injection timed operation Band heater Operating...

Page 28: ...SD CARD Rotating pressure gauge assembly display Germany not included 12 kg tank Double stage vacuum pump High efficiency refrigerant recovery over 95 Automatic oil injection timed operation 2 manual...

Page 29: ...included 20 kg tank Double stage vacuum pump High efficiency refrigerant recovery over 95 Anti contamination airtight oil bottles patent pending High precision automatic oil injection Automatic oil bo...

Page 30: ...embly display Germany not included 30 kg tank Double stage vacuum pump High efficiency refrigerant recovery over 95 Anti contamination airtight oil bottles patent pending High precision automatic oil...

Page 31: ...tanks Double stage vacuum pump High efficiency refrigerant recovery over 95 Anti contamination airtight oil containers patents pending High precision automatic oil injection Automatic oil bottle recog...

Page 32: ...rging stations 720R 760R 760R BUS 780R BI GAS 6 1 Front view 1 High pressure gauge HP 2 Low pressure gauge LP 3 Control panel display 4 Top panel 5 Body of the recharging station 6 Cylinder compartmen...

Page 33: ...illing 4 High visibility TFT colour display 5 Printer 6 Keypad The 720R charging stations are equipped with a blue high visibility LCD 80 character display with backlighting Supplied only with the cha...

Page 34: ...HP LP connections for R1234yf refrigerants 6 Setup for the Refrigerant Identifier 7 Service hose holder 8 Service hoses 9 VDC housing Available on all the charging of the Series 700R Available only o...

Page 35: ...are equipped with standard type bottles Not available on the charging station model 720R 6 3 1 Containers AIRTIGHT CONTAINERS Available on the 760R 760R BUS and 780R charging stations 1 Bottle unlock...

Page 36: ...3 Tank The standard bottles can be identified by their different capacity 250 ml PAG or POE oil 250 ml UV tracer 500 ml recovered oil 6 4 Left Side View 1 Main switch 2 Power supply cable connector 3...

Page 37: ...705R OFF ROAD 707R 710R 710L 712R 7 1 Front view KONFORT 705R 705R OFF ROAD 1 Dashboard 2 Body of the recharging station 3 Based on the model 705R Castors with brakes 705R OFF ROAD support stand The C...

Page 38: ...KONFORT 710R 710L 712R 1 Dashboard 2 Body of the recharging station 3 Cylinder compartment door 4 Castors with brakes The Control Unit is built in 38...

Page 39: ...ction 6 Keyboard KONFORT 707R 1 High Pressure gauge HP 2 Low Pressure gauge LP 3 Graphic LED display 240x128 COG 4 8 4 Printer connection 5 Keyboard KONFORT 710R 710L 712R 1 High Pressure gauge HP 2 L...

Page 40: ...KEYPAD 1 ENTER and BACK CANCEL keys 2 UP and DOWN arrow keys 3 Alphanumerical keypad 4 STOP key 5 INFO key 40...

Page 41: ...View KONFORT 705R 1 Handle 2 Main switch 3 Power supply cable connector 4 Castors with brakes KONFORT 705R OFF ROAD 1 Handle 2 Main switch 3 Power supply cable connector 4 Oversized and puncture proo...

Page 42: ...T 707R 1 Handle 2 Main switch 3 Power supply cable connector 4 Castors with brakes KONFORT 710R 710L 712R 1 Handle 2 SD CARD slot 3 LP and HP taps 4 Service hose holder 5 Castors with brakes Except 71...

Page 43: ...Tank 10 Scale lock unlock Only on the charging station model 705R OFF ROAD KONFORT 707R 1 SD CARD slot 2 HP LP quick fittings for the service hoses 3 Standard OIL PAG POE bottle for specific oil 4 Co...

Page 44: ...P LP quick fittings for the service hoses 6 Service bulkhead to access the filter 7 Service bulkhead to access the pump 7 3 1 Standard Bottles 1 Pneumatic connection 2 Tank cap 3 Tank The standard bot...

Page 45: ...Left Side View KONFORT 705R KONFORT 705R OFF ROAD KONFORT 707R KONFORT 710R 710L 712R 1 Fastening holes for the Flushing Kit 2 Pump oil level inspection 3 Main switch 4 Power supply cable connector 45...

Page 46: ...y the fittings Tag indicating the type of refrigerant used Pressure clip used to fasten the tag Technical Manual contains the description of the device user instructions to guarantee a correct use and...

Page 47: ...rts are missing Not required for the charging station model 780R BI GAS Already installed on the charging stations 705R 705R OFF ROAD 707R 710R 710L 8 2 GAS KIT installation This chapter describes the...

Page 48: ...screws 4 Attach the specific adhesive ring to the connection for the HP quick hose fitting 5 Repeat the operations up to here for in order to install the connection for the LP quick hose fitting as we...

Page 49: ...05 OFF ROAD 707R 760R 760R BUS 780R BI GAS You must always lock the scale before moving the equipment You must always unlock the scale before using the equipment KONFORT 705R OFF ROAD 707R Proceed as...

Page 50: ...of overturning Follow the safety rules provided in this manual Proceed as follows 1 Lock the refrigerant scale 2 Unlock the wheels if necessary and push the cart using the specific handle located on t...

Page 51: ...e SD CARD contains the database of the vehicles on which it is possible to carry out air conditioning service and allows you to automatically store each recharging service carried out You must insert...

Page 52: ...y 5 Repeat the operations indicated above if the paper does not come out 9 7 How to Fill the Bottles You must fill the oil and UV tracer bottles before use Fill the bottle with the correct type of oil...

Page 53: ...unction for the internal tank filling by selecting the option ADDITIONAL FUNCTIONS If you are working with the 780R charging station make sure to select the specific filling function for the gas you i...

Page 54: ...s until reaching the item LANGUAGE 5 Press 6 Press until reaching the item that corresponds to the desired language 7 Press 8 The language is set The procedure for setting the language is the same as...

Page 55: ...e device includes a demo mode Demo The device can be used in Demo mode for a maximum cycle of 15 power on power offs The equipment locks automatically at the end of the cycle and can no longer be used...

Page 56: ...the phase in progress at a specific time Name Symbol Colour Indicates Blink Code GAS Orange R134a is being used ON refrigerant is being used OFF device is turned off Green Using the refrigerant R1234...

Page 57: ...Key Name Function ENTER Allows you to confirm the selection made DELETE Allows you to delete data that has been entered STOP BACK CANCEL Allows you to instantly stop the phase in progress or go back...

Page 58: ...ixed on printer on line Flashing the printer is off line or there is no paper in the printer OFF printer off line The printer is automatically on line upon equipment startup Press if the status LED in...

Page 59: ...ns by unplugging the power supply cable either from the device or from the socket 12 2 Stopping the Equipment for Long Periods Should you intend to stop the equipment for a long period of time follow...

Page 60: ...slot 3 Gently press on the SD CARD to unlock it 4 Remove the SD CARD 5 Enter the SD CARD into the SD CARD READER 6 Connect the SD CARD READER to a PC 7 Copy the update into theSD CARD 8 Remove the SD...

Page 61: ...12 Once the update is complete the software restarts automatically 61 en...

Page 62: ...ce operation Frequency Dryer Filter Replacement When prompted by the device Mechanical Filter Replacement Along with the dehydrator filter replacement Vacuum pump oil replacement When prompted by the...

Page 63: ...r screws that block the bulkhead using an hexagonal wrench n 3 4 Remove the bulkhead KONFORT 707R 705R 705 OFF ROAD Following is the procedure for opening the service bulkheads correctly on the models...

Page 64: ...ile replacing the filter You must carefully read and understand this Operating Manual in order to perform the provided instructions correctly Before replacing the filter you must reset the filter coun...

Page 65: ...recharging station 720R 760R 760R BUS 780R BI GAS open the service lid 710R 710L 712R remove the service cover 707R 705R 705 OFF ROAD remove the front shield 2 Open the filter s blocking clip 3 Unscr...

Page 66: ...replaced Follow the same safety precautions indicated in the Dryer Filter Replacement chapter In models 705R 707R the mechanical filter is located over the dryer filter a Rilsan pipe connection mechan...

Page 67: ...O ring on the new filter on the side of the constant expansion valve connection 8 Remount the filter using the specific tools and tightening with a torque of approximately 17 Nm 14 1 3 How to Replace...

Page 68: ...ows 1 Disconnect the device from the power mains 2 Unscrew the oil drain cap 3 Wait for all the oil to drain from the pump Collect the recovered oil and dispose of it according to the regulations in f...

Page 69: ...e O rings Oil and UV bottles Make sure they are clear and not damaged Wheels Make sure the brakes are working properly Power supply cable Make sure there are no cuts scratches or burns 14 3 Periodical...

Page 70: ...rnal circuit making sure the internal storage tank is emptied as well 2 Take the device to a waste disposal centre For more information regarding the disposal consult the pamplet provided with the dev...

Page 71: ...16 DATA PLATE Every single device is accompanied by an identification data plate just as the one in the example provided below Where PS maximum operating pressure TS operating temperature 71 en...

Page 72: ...0 Kl 1 0 High pressure gauge mm 100 100 100 100 Low pressure gauge mm 80 80 80 80 Tank capacity kg 12 20 30 2 x 12 Service pipes length m 3 3 3 3 Filter assembly 1 combined filter mechanical filter 1...

Page 73: ...SAE J2099 150 SAE J2099 Recovery efficiency 95 SAE J2788 SAE J2843 95 SAE J2788 SAE J2843 95 SAE J2788 SAE J2843 95 SAE J2788 SAE J2843 Maximum operating pressure PS bar 20 20 20 20 Safety device cal...

Page 74: ...Power supply voltage V Only for Japan 230 230 100 230 230 100 Frequency Hz Only for Japan 50 50 50 60 50 50 50 60 Power W 770 770 900 770 74...

Page 75: ...pressure gauge mm 80 80 80 Tank capacity kg 10 20 20 Service pipes length m 3 3 3 Filter assembly 1 combined filter mechanical filter 1 combined filter mechanical filter 1 combined filter mechanical...

Page 76: ...SAE J2788 Maximum operating pressure PS bar 20 20 20 Safety device calibration bar 20 20 20 Operation temperature TS C 5 40 5 40 5 40 Storing temperature C 25 60 25 60 25 60 Dimensions mm H 1078 L 59...

Page 77: ...w pressure gauge mm 80 80 80 Tank capacity kg 10 10 10 Service pipes length m 3 3 3 Filter assembly 1 combined filter mechanical filter 1 combined filter mechanical filter 1 combined filter mechanical...

Page 78: ...SAE J2843 Maximum operating pressure PS bar 20 20 20 Safety device calibration bar 20 20 20 Operation temperature TS C 5 40 5 40 5 40 Storing temperature C 25 60 25 60 25 60 Dimensions mm H 1078 L 59...

Page 79: ...20 FLOW DIAGRAMS KONFORT 705R 705R OFF ROAD 79 en...

Page 80: ...KONFORT 707R 80...

Page 81: ...KONFORT 710R 710L 81 en...

Page 82: ...KONFORT 712R 82...

Page 83: ...KONFORT 720R 83 en...

Page 84: ...KONFORT 760R 760 BUS 84...

Page 85: ...KONFORT 780R BI GAS 85 en...

Page 86: ...bject to the direction and coordination activities of Opera Holding S r l Paid up share capital 1 000 000 R E A Economic Administrative Index No 208102 Legal Representative Bruno Vianello Phone 39 042...

Reviews: