Version: Leo 18 GT_GB_02-2008
43
/
24
The alarm STOP-switch stops immediately the explosive engine, you can restart after
the discoupling the STOP-switch.
2.
Operating with electric motor (Option)
The electrical connecting with feed cable
•
On the building area the operating can be assured only from appropriately
working up supplied units, which in working up and usage it is suitable to the
protective instructions .
•
Start the motor:
-
switching the key switch (4) on
-
pushing the green colour start button (8)
•
Stop the motor:
-
switching the key switch (4) off
-
pushing the emergency stop button
(or starting the combustion engine).
ATTENTION!
During operating the machine the key switch of the basket must
be in switched on position and the emergency stop buttons must
be in released position to ensure proper operation of the voice
and and light alarm signals.
Switching off the above mentioned switches is only allowed in
emergency situation or during setting the basic position of the
machine.
b) If the supplying of the input energy happens from extension cable, you must
keep strictly the following instructions:
•
If the cable long is 40 m, the section of the extension cable must be mini-
mum 3x2.5 mm
2
,
•
If the cable long is between 40 m and 80 m but maximum 80 m, the section
of the extension cable must be minimum 3 x 4 mm
2
.
Ignition of the Kubota
engine from the basket:
1. Start-Stop
Kubota engine
2. Oil pressure alarm
8. Time control start
push button and green
lamp
3. Emergency stop
4. Key switch