Shenzhen TestPad Electronic Co., Ltd.
http://www.test-pad.com
26
The third line indicates that cut-off voltage is 0.5V. When the operating voltage drops to the
cut-off voltage, the tester automatically cuts the operating current, thus to prevent battery
over-discharge by the electronic load from over-discharging the battery. the battery discharge by
electronic load. This function is available only when the tester works in CC, CR or CP mode. CV
indicates voltage control, so such function is unavailable when the tester works in CV mode.
Out: It indicates that the values below are the actual values measured.
OFF: It indicates that the tester is switched on. Press ENTER to toggle between On/Off.
ON: It indicates that the tester is switched off.
Vo=0.00V: It indicates that the measured voltage is 0V.
Io=0.003A: It indicates that the measured current is 0.003A (note that zero-point error may exist,
which can be eliminated or ignored).
Operation description:
1.
Press UP or DOWN to switch between three items: selecting working mode, adjusting value
to be set, and adjusting cut-off voltage (note that if CV mode is selected, the function of
adjusting cut-off voltage is unavailable for selection).
2.
Press LEFT or RIGHT to adjust the value of the current item.
3.
Press ENTER to enable or disable electronic-load.
4.
Press ESC to exit the electronic-load mode.