Shenzhen TestPad Electronic Co., Ltd.
http://www.test-pad.com
16
14. OVC-Max: This parameter can be adjusted only when the over-current test is enabled; it
can be increased or decreased by 0.1A, each time, and the maximum value is 12A.
15. R1-Min: This parameter can be adjusted only when the R1 test is enabled; it can be
increased or decreased by 0.1K, each time, and the maximum value is 999.9K.
16. R1-Max: This parameter can be adjusted only when the R1 test is enabled; it can be
increased or decreased by 0.1K, each time, and the maximum value is 999.9K.
17. R2-Max: This parameter can be adjusted only when the R2 test is enabled; it can be
increased or decreased by 0.1K, each time, and the maximum value is 999.9K.
18. R2-Min: This parameter can be adjusted only when the R2 test is enabled; it can be
increased or decreased by 0.1K, each time, and the maximum value is 999.9K.
19. CHECK ID: Select MOTO (indicating that the ID of an MOTO mobile phone can be
checked) or No (indicating that no ID is tested).
20. ID Type: Select one from 10 ID types and one self-learning ID type.
21. Short TEST: For Li-ion battery, enable or disable the test. For other battery types, this
function is unavailable.
22. Short TIME: It can be adjusted in the range of 1mS~200mS. If the tested battery does not
cut off the current within the specified period, it is deemed that the battery short-circuit test
fails.
23. Short Re: If Charge is selected, it indicates that the battery output is restored through
temporary charge. If OPEN is selected, it indicates that the battery output is restored
through load disconnection. If the battery voltage is not restored to the lower threshold, it is
deemed that the short-circuit test fails.
24. OPEN time: It is valid if Short Re is set to OPEN. It indicates that the entire load will be
disconnected after the short-circuit protection and then the voltage will be tested after the
time set here.
25. detV_Max (0.5C): The maximum value is 1V.
26. Exit Mode: If Save is selected, the settings after each adjustment will be saved in the
internal memory and will not be lost after the device power-off. If NoSave is selected, the
settings will not be saved and will be lost after the device power-off. If Reset is selected,
the default settings will be restored after you exit the menu.
After all the parameters are set, press ENTER. Then the tester will automatically start and follow
the process below to test all the selected items: