![TestPad BTS-2002H Manual Download Page 22](http://html.mh-extra.com/html/testpad/bts-2002h/bts-2002h_manual_1092569022.webp)
Shenzhen TestPad Electronic Co., Ltd.
http://www.test-pad.com
22
RUN: Run mode
PAUSE: Pause mode
ERROR: Operation error
COMP: Operation completion
(Line 2)
RUN TIME: 00:03:17: It indicates the accumulated duration of the test.
V=8.42V: It indicates the voltage of the battery. If “+/-“ is displayed, it indicates that the
battery is connected reversely.
I=0.683A: It indicates the current of the battery.
If the battery is being charged, it indicates the charge current. If the battery is being
damaged, it indicates the discharge current.
In the charge mode, if “CHARGE CAP: 26mAH” is displayed, it indicates that the charged
capacity is 26mAH.
In the discharge mode, if “DISCHR CAP: 1234mAH” is displayed, it indicates that the
discharged capacity is 1234mAH.
If the test is completed and the over-charge test and over-discharge test are enabled, the
over-charge voltage, the over-discharge protection current, and the finally discharged
capacity will be displayed here in turn.
In case of a fault, the test is aborted, and the fault cause is displayed here.
Caution: If the capacity of Nickel-Metal hydride battery or Nickel-Cadmium battery need be
tested, our delivery-attached temperature sensor is recommended. Place the temperature sensor
close to the surface of the battery to be tested, and connect the temperature sensor to the P- and R2
of the tester, thus to ensure safe charge.