Laboratory mortar mixer
1.0206.01
10
4.2. Improper use
The mortar mixer may only be operated in a technically perfect condition.
Only use the mortar mixer for the described use, any improper use shall result in the loss
of the warranty claim.
Manipulations and modifications to the mortar mixer (electrical, mechanical changes, etc.)
that have not been authorised in a written agreement with the manufacturer are consid-
ered to be prohibited and the manufacturer does not accept any claims for damages.
We recommend only using original spare parts and accessories; otherwise the manufac-
turer assumes no liability.
Ensure that no hazardous situations occur during the work. The mortar mixer must be
switched off immediately if it does not work properly and the manufacturer or their author-
ised service personnel must be notified immediately.
Not intended use and therefore not permissible are the following:
the mixing of substances other than those specified in 4.1
overfilling the mixing bowl
the installation and operation of the mixer in ambient conditions other than those
specified in 6.1
4.3. Information on the CE symbol
TESTING Bluhm & Feuerherdt test equipment bear the CE symbol.
The CE marking confirms the conformity of the product with the EC directives to be taken
into account for the product and compliance with the "essential requirements" defined
therein, the generally applicable level of protection. The conformity assessment proce-
dure has been carried out in accordance with the applicable EC directives. The Council
Decision 93/465/EEC on the modules to be used in the technical harmonisation directives
for the different phases of the conformity assessment procedures and the rules for the
affixing and use of the CE marking shall be taken into account.
4.4. Obligation of the operator
The operator must ensure that they do not put themselves or any others at risk. Only
persons who have been instructed in the operation are allowed to operate the device
independently.
If the operating safety is compromised by faults or damage to the device, it must be taken
out of operation immediately and must only be used again after the elimination of all haz-
ards.
Summary of Contents for 1.0206.01
Page 47: ...Laboratory mortar mixer 1 0206 01 47 21 I O board...
Page 48: ...Laboratory mortar mixer 1 0206 01 48 22 Circuit diagram...
Page 50: ...Laboratory mortar mixer 1 0206 01 50 23 2 Mixing program 2 according to EN 480 T1...
Page 51: ...Laboratory mortar mixer 1 0206 01 51 23 3 Mixing program 3 according to EN 196 T3...
Page 52: ...Laboratory mortar mixer 1 0206 01 52 23 4 Mixing program 4 according to EN 196 T9...
Page 54: ...Laboratory mortar mixer 1 0206 01 54 24 2 Mixing program 2 according to ASTM C451...