![TESTING 1.0204.LV Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/testing/1-0204-lv/1-0204-lv_operating-instructions-manual_1092040015.webp)
Laboratory mortar mixers
Model 1.0204.LV
15
5.2 Safety devices
The mortar mixer is equipped with the following safety devices:
1.
EMERGENCY STOP switch
When the EMERGENCY STOP switch is pressed, the drive motor is disconnected
from the 24V supply.
To put the mortar mixer back into operation, the EMERGENCY STOP switch must
be returned to its basic position by turning it in the direction of the arrow.
2.
Inductive, electronic proximity switch
The proximity switch above the mixing bowl holder detects the edge of the mixing
bowl.
If the mixing bowl is not inserted into the mounting, the safety module prevents the
mortar mixer from being operated. The motor cannot be powered up.
3.
Fixed protective cover
The mixing bowl is covered in the mixing position by a fixed protective cover which
encloses the stirrer on all sides.
6. Preparations for start-up
6.1 Installation site/environmental conditions
Warning
The operation of the mortar mixer is
permitted only in dry rooms!
The following limit values apply:
Ambient temperature
DIN EN 60204-1, 4.4.2
+5
C to
+40
C
Humidity
DIN EN 60204-1, 4.4.3
30% to
95%
Note
Place the mortar mixer on a stable, level surface.
6.2 Electrical connection
An IEC power connection cable is used to provide the power connection of the mortar
mixer. The mortar mixer contains an IEC power connector (IEC 60320 C14).
Voltage: 85-264V~; Frequency: 47-63Hz