TP-K01 

Bead 
probe 

-50

  to 200

 

-58

  to 392

 

2.2

  or 

0.75

 

(

3.6

  or 

0.75

with Teflon tape 
insulation. Maximum 
insulating 
temperature: 260

 

TP-K02 

immersion 
probe 

-50

  to 1000

 

-58

  to 1832

 

2.2

  or 

0.75

 

(

3.6

  or 

0.75

3.2

φ×

150

  metal 

sheath 100

 

Compensating wire 

TP-K03 

Surface 
probe 

-50

  to 750

 

-58

  to 1382

 

2.2

  or 

0.75

 

(

3.6

  or 

0.75

100

  Compensating 

wire 12.5

φ

x 94

 

handle 

 
 
TP-K01: Available for general condition, especially for 

complex and any place hard to reach. 

 

 
 
 

13 

TP-K02: Available for temperature measurement of liquid, 

gels or air. 

 

 

 
TP-K03: Available for flat or curved surface measurement. 

 

 

 
 

 

 
 
 
 
 

14

 

 
 

Summary of Contents for TES-1313

Page 1: ...90 Read the following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may...

Page 2: ...mperature Coefficient 0 01 of reading 0 03 per 0 06 per outside the specified 18 to 28 64 to 82 range Below 100 148 add 0 04 of reading for J K E and N type and 0 08 of reading for T type 2 Input Prot...

Page 3: ...X MIN AVG reading C Time display Time display 100 hour clock shows elapsed time when MAX MIN or AVG is on D Auto power off mark 2 H HOLD key Press H HOLD key to freeze or unfreeze the display reading...

Page 4: ...again to exit this mode 11 C F K key Press C F K key to select Celsius Fahrenheit or Kelvin K temperature scale 12 key Press backlight key to turn the backlight on and off The backlight turns off aft...

Page 5: ...to toggle showing the elapsed time hour min and min sec on LCD The elapsed time since entering reading mode or the time at which the MAX MIN or AVG occurred appears on the time display Press MX MN ke...

Page 6: ...function only perform on the main display temperature value the resolution of setting value is one degree and regardless the temperature units Press SET key one time enter to Alarm High limit value s...

Page 7: ...ter will enter to the sleep mode if no key pressed occurs for 30 minutes Press key to turn off the meter Press and hold down key then press key to turn on the meter the auto power off function will be...

Page 8: ...o 1832 2 2 or 0 75 3 6 or 0 75 3 2 150 metal sheath 100 Compensating wire TP K03 Surface probe 50 to 750 58 to 1382 2 2 or 0 75 3 6 or 0 75 100 Compensating wire 12 5 x 94 handle TP K01 Available for...

Page 9: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Sep 2004 1...

Reviews: