3. FRONT PANEL DESCRIPTION 

T1

KJTERSN

min:sec

hour:min

TYPE

INTERVAL

T1

ALM

Lo

Hi

AVG

-

MX MN

C

K

F

13

4

6

7

5

3

D

2

1

C

11

8

10

9

12

B

A

 

min:sec

hour:min

TYPE

KJTERSN

Hi

Lo

ALM

F

K

AVG

MN

MX

C

 

(1). LCD Display :   

A. Main display : Temperature reading. 

B. Secondary display 

:

 MAX, MIN, AVG reading. 

C.  Time  display 

:

  Time  display  (100-hour  clock), 

shows elapsed time when MAX, 
MIN or AVG is on. 

D. Auto power off mark (:). 

(2). 

 

H

 

  HOLD key :

 Press 

 

H

 

  HOLD key to freeze or 

unfreeze the display reading. 

(3). 

 

Power key : 

Press 

  key to turn the meter on 

or off. 

(4). MX/MN key :   

 Press "MX/MN" key to step through the maximum, 

minimum, and average readings. 

  Press  "MX/MN"  key  for  2  seconds  to  exit  MX/MN 

mode. 

(5).  MEM  key  : 

Press  "MEM"  key  each  time,  stores  a 

single set of logged reading in memory. 

Summary of Contents for TES-1313

Page 1: ...90 Read the following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may...

Page 2: ...mperature Coefficient 0 01 of reading 0 03 per 0 06 per outside the specified 18 to 28 64 to 82 range Below 100 148 add 0 04 of reading for J K E and N type and 0 08 of reading for T type 2 Input Prot...

Page 3: ...X MIN AVG reading C Time display Time display 100 hour clock shows elapsed time when MAX MIN or AVG is on D Auto power off mark 2 H HOLD key Press H HOLD key to freeze or unfreeze the display reading...

Page 4: ...again to exit this mode 11 C F K key Press C F K key to select Celsius Fahrenheit or Kelvin K temperature scale 12 key Press backlight key to turn the backlight on and off The backlight turns off aft...

Page 5: ...to toggle showing the elapsed time hour min and min sec on LCD The elapsed time since entering reading mode or the time at which the MAX MIN or AVG occurred appears on the time display Press MX MN ke...

Page 6: ...function only perform on the main display temperature value the resolution of setting value is one degree and regardless the temperature units Press SET key one time enter to Alarm High limit value s...

Page 7: ...ter will enter to the sleep mode if no key pressed occurs for 30 minutes Press key to turn off the meter Press and hold down key then press key to turn on the meter the auto power off function will be...

Page 8: ...o 1832 2 2 or 0 75 3 6 or 0 75 3 2 150 metal sheath 100 Compensating wire TP K03 Surface probe 50 to 750 58 to 1382 2 2 or 0 75 3 6 or 0 75 100 Compensating wire 12 5 x 94 handle TP K01 Available for...

Page 9: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Sep 2004 1...

Reviews: