Specifications

Electrical rating:

  • 24 VAC (18-30 VAC) 

 

 

• 4 amp maximum total load

 

• 1 amp maximum per terminal

Temperature control range: 

45°F to 90°F (7°C to 32°C)   

Accuracy:

 ± 1°F (± 0.5°C)

System configurations:

 2-stage heat, 1-stage cool, heat pump, gas, oil, electric

Timing:

  Anti-short Cycle: 4 minutes

 

Backlight Operation: 5 seconds after mode change or button press

Terminations:

 R, C, W1/O/B, Y, W2, E, G

Important Safety Information

WARNING!

Always turn off power at the main power supply before installing, cleaning, 
or removing thermostat.

• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• Do not short across terminals of gas valve or system control to test operation; this will damage your 

thermostat and void your warranty

• All wiring must conform to local and national electrical and building codes
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage 

your A/C system and cause personal injuries

• Use this thermostat only as described in this manual

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing 

the fuse or switching the appropriate circuit breaker to the OFF position before 
removing the existing thermostat.

1.  Turn off power to the heating and cooling system by removing the fuse or switching the 

appropriate circuit breaker off.

2.  Remove cover of old thermostat. This should expose the wires.
3.  Label the existing wires with the enclosed wire labels before removing wires.
4.  After labeling wires, remove wires from wire terminals.
5.  Remove existing thermostat base from wall.
6.  Refer to the following section for instructions on how to install this thermostat.

To Remove Existing Thermostat

Package Contents/Tools Required

Package includes:

 

SC2311L

 thermostat on base, thermostat cover, wiring labels, screws and wall 

anchors, Installation, Operation and Application Guide

Tools required for installation:

 Drill with 3/16” bit, hammer, screwdriver

2 Heat/1 Cool

Manual Changeover

Hardwired

SC2311L

Non-Programmable Electronic Thermostat

Installation, Operation & Application Guide

For more information on our complete range of American-made 
products – plus wiring diagrams, troubleshooting tips and more, 
visit us at 

www.icmcontrols.com

•  Configurable
•  2-Stage Heat/1-Stage Cool Systems
•  Heat Pump Systems
•  Backlit Display
•  Field Temperature Calibration
•  Status Indicator Light
•  Relay Outputs 

 

(minimum voltage drop in thermostat)

•  Ideally Suited for:

– 

Residential (New Construction/Replacement) 

– 

Light Commercial

Parts Diagram

Down 

button

Up 

button

Left switch

Reset switch

RESET

LEFT

RIGHT

FP

R

C

W

O/

B

Y

W2

E

G

Field 

programming 

pins

Right switch

Mode switch

Fan switch

Status Led

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing 

the fuse or switching the appropriate circuit breaker to the OFF position before 
removing the existing thermostat.

 

IMPORTANT:

  Thermostat installation must conform to local and national building and 

electrical codes and ordinances. 

 

 

Note:

  

Mount the thermostat about four feet above the floor. Do not mount the thermostat 

on an outside wall, in direct sunlight, behind a door, or in an area affected by a vent 

or duct.

1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate 

circuit breaker off.

2.  To remove cover, insert and twist a coin or screwdriver in the slots on top of the thermostat.
3.  Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through 

the wire opening in the base of the thermostat).

4.  Mark the placement of the mounting holes.
5.  Set thermostat base and cover away from working area.
6.  Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
7.  Use a hammer to tap supplied anchors in mounting holes.
8.  Align thermostat base with mounting holes and feed the control wires through wire opening.
9.  Use supplied screws to mount thermostat base to wall.
10. Insert stripped, labeled wires in matching wire terminals. See “Wiring Diagrams” section of this 

manual.

 

CAUTION!

Be sure exposed portion of wires does not touch other wires.

11.  Gently tug wire to be sure of proper connection. Double check that each wire is connected to the 

proper terminal. 

12. Replace cover on thermostat by snapping it in place.
13. Turn on power to the system at the main service panel.
14. Test thermostat operation as described in “Testing the Thermostat”.

To Install Thermostat

Terminal Designator Descriptions

 

R  – 24 VAC hot

 

C  – 24 VAC common

 W1/O/B  – Configurable
 

W1  – 1st stage heat for non-hp systems

 

O  – cool active reversing valve

 

B  – heat active reversing valve

 

Y  – 1st stage cool, 1st stage heat for heat pumps

 

W2  – 2nd stage heat for heat pump, non-heat pump, and emergency heat

 

E  – 1st stage heat for Emergency Heat operation 

 

G  – Fan

SC2311L Output Chart

1

ST

 Cool

1

ST

 Heat

2

ND

 Heat

Heat/Cool

Y, G

W1, G*

W1, W2, G*

Heat Pump (One Compressor)

Y, G, O

Y, G, B

Y, W2, G, B

Emergency Heat HP

N/A

E, G

E, W2, G

* G not energized when configured as a gas/oil system  

The 

SC2311L

 thermostat is configurable for different systems. The configuration directly effects the 

outputs.
Use the output chart to correctly configure and wire the thermostat to your system.

Second

 

Heating Control

First

 

Heating Control

Fan

 

Control

Electric Heat

Single Transformer

Second

 

Heating Control

First

 

Heating Control

Gas/Oil Heat

Single Transformer

Wiring Diagrams

Cooling Control

Fan

 

Control

Second

 

Heating Control

First

 

Heating Control

Fan

 

Control

Cooling Control

Single Transformer

Single Transformer

Single Compressor

2

nd

 Stage

Heat

Reversing

 

Valve

Compressor

Emergency

 

Heat

Fan

 

Control

1. 

Temperature Scale (F or C)

 – Choose Fahrenheit or Celsius.

 

Press the 

up

 or 

down

 button to select.

  Press the

 

RIGHT

 

button to advance to the next screen.

2. 

1

st

 Stage Temperature Differential

 (1°F to 5°F) (0.5°C to 2.5°C)

Set the number of degrees between your “setpoint” temperature and your “turn 
on” temperature.

  Press the

 up

 or 

down

 button to set differential value.

  Press the 

RIGHT

 button to advance to the next screen.

Configuration Mode Settings

The configuration mode is used to set the 

SC2311L

 to match your heating/cooling system. The 

SC2311L

 functions with heat pump, air conditioning, gas, oil or electric heat systems.

To configure the 

SC2311L

, perform the following steps:

1.  Remove the cover of the thermostat by gently pulling on one of the top corners.
2.  Simultaneously hold the 

LEFT

 and 

RIGHT

 buttons in for 5 seconds while the 

SC2311L

 is in OFF 

mode.

3.  Press the 

up

 or 

down

 button to change settings within each screen.

4.  Press the 

RIGHT

 button to advance to the next screen.

 

 

Note:

 

The 

LEFT

 button will return you to the previous screen.

5.  To exit configuration mode, slide the Mode switch to Heat or Cool.

3. 

2

nd

 Stage Temperature Differential

 (1°F to 5°F) (0.5°C to 2.5°C)

Set the number of degrees between when stage 1 turns on and when stage 2 
turns on.

  Press the 

up

 or 

down

 button to set differential value.

  Press the 

RIGHT

 button to advance to the next screen.

5. 

Heat Source 

(o, b, g, E)

Change between “o” Heat pump cool active, “b” Heat pump heat active, “g” 
(Gas) and “E” (Electric).

  Press the 

up

 or 

down

 button to set heat source.

  Press the 

RIGHT

 button to advance to the next screen.

4. 

Staged Off Outputs

  

  Select whether the outputs for heating and cooling are staged off 

independently or are satisfied simultaneously.

  1 = outputs staged off independently     
  0 = outputs off simultaneously
  Press the 

up

 or 

down

 

button to set.

 

Press the

 

RIGHT 

button to advance to the next screen.

6.

  Auxiliary Delay ON

 – (0-30 minutes) – Set the delay time in minutes for auxiliary 

heat  to be locked out after a call for second stage. This extra savings feature is 
used to temporarily lock out auxiliary heat devices, allowing just heat pump to try 
to satisfy heat call.

  Press the 

up

 or 

down

 button to select.

  Press the 

RIGHT 

button to advance to the next screen

7. 

Lockout 

(0°F-8°F) (0°C-4°C)

 –

 Select the number of degrees set temperature 

can be changed during keypad lockout

 

Press the

 

up

 or 

down

 button to select.

 

Press the

 

RIGHT

 button to advance to the next screen.

8. 

Maximum Heat Setpoint

 (45°F to 90°F) (7°C to 32°C) 

  Adjust to control the maximum Heat set temperature allowed.
  Press the 

up

 or 

down

 button to select.

  Press the

 

RIGHT

 button to advance to the next screen.

9. 

Minimum Cool Setpoint

 (45°F to 90°F) (7°C to 32.0°C) 

  Adjust to control the minimum Cool set temperature allowed.
  Press the 

up

 or 

down

 button to select.

  Press the

 

RIGHT

 button to advance to the next screen.

10. 

Room temperature offset

 (+9°F to -9°F) (+4.5°C to -4.5°C) 

 

Adjust to calibrate displayed room temperature to match actual room 
temperature. 

 

 

Note:

 

When not set to 0, ROOM

 will display.

 

Press the 

up

 or 

down

 button to select.

 

Press the

 

RIGHT

 button to advance to the next screen.

11. 

Maximum compressor cycles allowed per hour

 (-, 2-6) 

 

  - = as many as needed, and 2-6 = maximum cycles/hour

 

Press the 

up

 or 

down

 button to select.

 

Press the 

RIGHT

 button to advance to the next screen.

12. 

Cooling Fan Delay Off Time

 (0, 30, 60, 90 seconds) 

 

Select the fan purge time for cooling.

 

Press the 

up

 or 

down

 button to select.

 

Press the

 

RIGHT 

button to advance to the next screen.

13. 

Status Indicator Light

 (Lt 0, 1, 2) 

 

0 = Status indicator never on     

 

1 = Status indicator on with first stage

 

2 = Status indicator on with second stage

 

Press the 

up

 or 

down

 button to select.

 

 

Note:

 

Red light indicates heating cycle and green light indicates cooling cycle.

 

Slide the Mode switch to Heat or Cool to exit configuration.