(6). SET key :

   

 Press "SET" key to enter alarm setting mode. 

  Press  "SET"  key  for  2  seconds  to enter  or  exit 

alarm mode. 

 
 
 

5

 

(7). 



 Key : 

  Press 

  or

 

  key  to  increase  or  decrease  the 

value for high/lower alarm settings. 

 Press 

 or

 

 

key to increase or decrease the 

READ mode memory location.

 

(8). 

 

key : 

 Press "

 " key to store alarm limit value setting. 

 Press "

 " key to toggle showing the "hour : min" 

and  "  min  :  sec"  elapsed  time  in  the  MX/MN 
mode. 

(9).

  TYPE  key:

  Press  "TYPE"  key  to  select  the 

thermocouple  type  (K,  J,  E,  T,  R,  S, 
N).

 

(10). READ key :

 Press "READ" key to show manual 

memory  logged  reading,  press 
again to exit this mode. 

(11).  C/F/K  key  :

  Press  C/F/K  key  to  select  Celsius 

(

),  Fahrenheit  (

)  or  Kelvin  (K) 

temperature scale. 

(12). 

  key  :

  Press  backlight  key  to  turn  the 

backlight  on  and  off.    The  backlight 
turns off after 13 seconds. 

(13). Input : 

Thermocouple input. 

 
 
 
 
 

4. OPERATION INSTRUCTIONS 

WARNING 

  To  avoid  electrical  shock  or  personal  injury,  do 

not  apply  more  than  20Vrms,  between  the 
thermocouples,  or  between  any  thermocouple 
and earth ground.

 

4-1 Temperature Measurement 

 Press " 

  " key to turn on the thermometer. 

 Plug the thermocouple into the thermocouple input.   

If  no  thermocouple  is  plugged  into  the  selected 
input or the thermocouple is "open", the display will 
show "- - - -.-". 

 Press "C/F/K" key to the desired temperature 

scale. 

  Press  "TYPE"  key  to  select  the  thermocouple  you 

Summary of Contents for TES-1313

Page 1: ...90 Read the following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may...

Page 2: ...mperature Coefficient 0 01 of reading 0 03 per 0 06 per outside the specified 18 to 28 64 to 82 range Below 100 148 add 0 04 of reading for J K E and N type and 0 08 of reading for T type 2 Input Prot...

Page 3: ...X MIN AVG reading C Time display Time display 100 hour clock shows elapsed time when MAX MIN or AVG is on D Auto power off mark 2 H HOLD key Press H HOLD key to freeze or unfreeze the display reading...

Page 4: ...again to exit this mode 11 C F K key Press C F K key to select Celsius Fahrenheit or Kelvin K temperature scale 12 key Press backlight key to turn the backlight on and off The backlight turns off aft...

Page 5: ...to toggle showing the elapsed time hour min and min sec on LCD The elapsed time since entering reading mode or the time at which the MAX MIN or AVG occurred appears on the time display Press MX MN ke...

Page 6: ...function only perform on the main display temperature value the resolution of setting value is one degree and regardless the temperature units Press SET key one time enter to Alarm High limit value s...

Page 7: ...ter will enter to the sleep mode if no key pressed occurs for 30 minutes Press key to turn off the meter Press and hold down key then press key to turn on the meter the auto power off function will be...

Page 8: ...o 1832 2 2 or 0 75 3 6 or 0 75 3 2 150 metal sheath 100 Compensating wire TP K03 Surface probe 50 to 750 58 to 1382 2 2 or 0 75 3 6 or 0 75 100 Compensating wire 12 5 x 94 handle TP K01 Available for...

Page 9: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Sep 2004 1...

Reviews: