• If there is reason to believe that safe operation is no longer possible, put the device
out of operation and secure it against unintended operation. Safe operation is no
longer possible if:
- the product shows visible damages,
- the product no longer works and
- the product was stored under unfavourable conditions for a long period of time,
- the product was subject to considerable transport stress.
• The product should not be connected immediately after it has been brought from an
area of cold temperature to an area of warm temperature. Condensed water might
destroy the product. Wait until the product stabilises to adapt to the new ambient
temperature before use.
• The device must not be exposed to humidity or liquids.
• Steam, dust, smoke and/or vapours can prevent accurate measurement by obstruc-
ting the thermometer’s optics.
• The manufacturer or supplier accepts no responsibility whatsoever for incorrect
displays or the consequences which can arise from such incorrect displays.
Laser
• Never look into the laser beam and never point it at people or animals. Laser radiation
can cause damage to eyes or skin.
• This product is equipped with a class 2 laser according to EN 60 825-1. Never open
the device.
• Any adjustment or service work is only to be carried out by qualified personnel who
are familiar with the risks involved. Improperly made adjustments may result in hazar-
dous laser radiation.
• During operation of the device, the laser has to be directed in such a way that no
person is located within the range of projection and that unwanted reflected rays (e.g.
due to reflecting objects) do not get into the range of any person.
• If possible, restrict the range of radiation by using screens or partitions.
• Never open the device. Any adjustment or service work is only to be carried out by
qualified personnel who are familiar with the risks involved. Improperly made adjust-
ments may result in hazardous laser radiation.
• Included in the delivery are reference signs for the laser in different languages. In
case the sign on the laser is not written in the language of your country, please fix the
respective sign onto the laser.
Battery
• Observe correct polarity while inserting the battery.
• Remove the battery if the device is not used for a long period of time to avoid damage
through leaking. Leaking or damaged batteries might cause acid burns when contact
with skin, therefore use suitable protective gloves to handle corrupted batteries.
• Keep batteries out of reach of children. Do not leave the battery lying around, as there
is risk, which children or pets could swallow it.
• Make sure that batteries are not dismantled, short-circuited or thrown into fire.
• Never recharge non-rechargeable batteries. There is a risk of explosion!
Miscellaneous
• The product must not be used for medical or public purposes.
• Repair works must only be carried out by a specialist/ specialist workshop.
•
If there are any technical questions, please contact:
International:
www.conrad.com/contact
United Kingdom:
www.conrad-electronic.co.uk/contact
OPERATING ELEMENTS
1. Battery compartment
2. “LCD/Laser” button
3. “MAX/MIN” button
4. LC display
5. Laser pointer
6. Infrared sensor
7. “ºC/ºF” button
8. Trigger
G
OPERATING INSTRUCTIONS
IR-THERMOMETER IR 260-8S
ITEM NO. 100980
INTRODUCTION
Dear customer,
Thank you for making the excellent decision to purchase this Voltcraft
®
product.
You HAVE acquired a high-quality product with a name that stands for outstanding products in the
field of measuring, charging and power technology, which excel due to professional competence
and constant innovation.
With Voltcraft
®
, you will be able to cope even with the most difficult tasks whether you are an
ambitious hobby user or a professional user. Voltcraft
®
offers reliable technology combined with
exceptional value for money.
Therefore, we are absolutely sure: that starting to use Voltcraft will also be the start of a long,
successful relationship.
We hope you will enjoy using your new Voltcraft
®
product!
INTENDED USE
The IR-260-8S is a device for non-contact temperature measurement, which uses the infrared
energy emitted by an object to determine the temperature. The IR-260-8S thermometer is ideal
for measuring the temperature of hot, hard-to-reach, or moving objects. It measures the surface
temperature of an object. However, it cannot make measurements through transparent surfaces
such as glass or plastic. The thermometer has a temperature range of -30ºC to 260ºC. Power is
supplied by a 9 V battery.
Measurements must not be carried out under unfavourable ambient conditions. Adverse ambient
conditions include:
• Moisture or excessive humidity
• Dust or combustible gases, vapours or solvents
• Thunderstorms or conditions as during a storm (e.g. strong electrostatic fi elds should be avoided)
This product fulfils European and national requirements related to electromagnetic compa-
tibility (EMC). CE conformity has been verified and the relevant statements and documents
have been deposited at the manufacturer.
Unauthorised conversion and/or modification of the device are inadmissible because of safety and
approval reasons (CE). Any usage other than described above is not permitted and can damage the
product and lead to associated risks such as short-circuit, fire, electric shock, etc. Please read the
operating instructions thoroughly and keep them for further reference.
CONTENT OF DELIVERY
• Infrared thermometer
• 1 x 9 V battery
• Operating instructions
SAFETY INSTRUCTIONS
We do not assume liability for resulting damages to property or personal injury if
the product has been abused in any way or damaged by improper use or failure to
observe these operating instructions. The warranty/ guarantee will then expire!
The icon with exclamation mark indicates important information in the operating
instructions. Carefully read the whole operating instructions before operating the
device, otherwise there is risk of danger.
Persons / Product
• The product is not a toy and should be kept out of reach of children and pets!
• On commercial premises, the accident prevention regulations of the Association of
Industrial Professional Associations with respect to electrical systems and operating
equipment must be observed.
• In schools, training centres, Hobby and DIY workshops, the handling of measuring
appliances must be responsibly supervised by trained personnel.
• The device may only be operated in a closed, dry room. The space may not become
damp or wet as this poses a risk of electrocution!
• The product must not be subjected to heavy mechanical stress or intense vibration.
• The product must not be exposed to electromagnetic fields, static electrical fields,
extreme temperatures, direct sunlight or dampness.
VERSION 07/15