background image

 

•   If there is reason to believe that safe operation is no longer possible, put the device 

out of operation and secure it against unintended operation. Safe operation is no 

longer possible if:

 

  -  the product shows visible damages,

 

  -  the product no longer works and

 

  -  the product was stored under unfavourable conditions for a long period of time,

 

  -  the product was subject to considerable transport stress.

 

•   The product should not be connected immediately after it has been brought from an 

area of cold temperature to an area of warm temperature. Condensed water might 

destroy the product. Wait until the product stabilises to adapt to the new ambient 

temperature before use.

 

•   The device must not be exposed to humidity or liquids.

 

•   Steam, dust, smoke and/or vapours can prevent accurate measurement by obstruc-

ting the thermometer’s optics.

 

•   The manufacturer or supplier accepts no responsibility whatsoever for incorrect 

displays or the consequences which can arise from such incorrect displays.

 

Laser

 

•   Never look into the laser beam and never point it at people or animals. Laser radiation 

can cause damage to eyes or skin.

 

•   This product is equipped with a class 2 laser according to EN 60 825-1. Never open 

the device. 

 

•   Any adjustment or service work is only to be carried out by qualified personnel who 

are familiar with the risks involved. Improperly made adjustments may result in hazar-

dous laser radiation.

 

•   During operation of the device, the laser has to be directed in such a way that no 

person is located within the range of projection and that unwanted reflected rays (e.g. 

due to reflecting objects) do not get into the range of any person.

 

•   If possible, restrict the range of radiation by using screens or partitions.

 

•   Never open the device. Any adjustment or service work is only to be carried out by 

qualified personnel who are familiar with the risks involved. Improperly made adjust-

ments may result in hazardous laser radiation.

 

•   Included in the delivery are reference signs for the laser in different languages. In 

case the sign on the laser is not written in the language of your country, please fix the 

respective sign onto the laser.

     

 

Battery

 

•  Observe correct polarity while inserting the battery.

 

•   Remove the battery if the device is not used for a long period of time to avoid damage 

through leaking. Leaking or damaged batteries might cause acid burns when contact 

with skin, therefore use suitable protective gloves to handle corrupted batteries.

 

•   Keep batteries out of reach of children. Do not leave the battery lying around, as there 

is risk, which children or pets could swallow it.

 

•   Make sure that batteries are not dismantled, short-circuited or thrown into fire.

 

•   Never recharge non-rechargeable batteries. There is a risk of explosion!

 

Miscellaneous

 

•   The product must not be used for medical or public purposes.

 

•   Repair works must only be carried out by a specialist/ specialist workshop.

 

• 

If there are any technical questions, please contact:

 

  International:  

www.conrad.com/contact

 

  United Kingdom:  

www.conrad-electronic.co.uk/contact

OPERATING ELEMENTS 

1.  Battery compartment
2.  “LCD/Laser” button
3.  “MAX/MIN” button
4.  LC display
5.  Laser pointer
6.  Infrared sensor
7.  “ºC/ºF” button
8.  Trigger

G

 OPERATING INSTRUCTIONS

IR-THERMOMETER IR 260-8S

ITEM NO. 100980

INTRODUCTION

Dear customer,

Thank you for making the excellent decision to purchase this Voltcraft

®

 product.

You HAVE acquired a high-quality product with a name that stands for outstanding products in the 

field of measuring, charging and power technology, which excel due to professional competence 

and constant innovation.
With Voltcraft

®

, you will be able to cope even with the most difficult tasks whether you are an 

ambitious hobby user or a professional user. Voltcraft

®

 offers reliable technology combined with 

exceptional value for money.
Therefore, we are absolutely sure: that starting to use Voltcraft will also be the start of a long, 

successful relationship.

We hope you will enjoy using your new Voltcraft

®

 product!

INTENDED USE

The IR-260-8S is a device for non-contact temperature measurement, which uses the infrared 

energy emitted by an object to determine the temperature. The IR-260-8S thermometer is ideal 

for measuring the temperature of hot, hard-to-reach, or moving objects. It measures the surface 

temperature of an object. However, it cannot make measurements through transparent surfaces 

such as glass or plastic. The thermometer has a temperature range of -30ºC to 260ºC. Power is 

supplied by a 9 V battery.
Measurements must not be carried out under unfavourable ambient conditions. Adverse ambient 

conditions include:
•  Moisture or excessive humidity
•  Dust or combustible gases, vapours or solvents
•  Thunderstorms or conditions as during a storm (e.g. strong electrostatic fi elds should be avoided)

This product fulfils European and national requirements related to electromagnetic compa-

tibility (EMC). CE conformity has been verified and the relevant statements and documents 

have been deposited at the manufacturer.

Unauthorised conversion and/or modification of the device are inadmissible because of safety and 

approval reasons (CE). Any usage other than described above is not permitted and can damage the 

product and lead to associated risks such as short-circuit, fire, electric shock, etc. Please read the 

operating instructions thoroughly and keep them for further reference.

CONTENT OF DELIVERY

•  Infrared thermometer
•  1 x 9 V battery
•  Operating instructions

SAFETY INSTRUCTIONS

 

 

We do not assume liability for resulting damages to property or personal injury if 

the product has been abused in any way or damaged by improper use or failure to 

observe these operating instructions. The warranty/ guarantee will then expire!

 

 The icon with exclamation mark indicates important information in the operating 

instructions. Carefully read the whole operating instructions before operating the 

device, otherwise there is risk of danger.

 

Persons / Product

 

•   The product is not a toy and should be kept out of reach of children and pets!

 

•   On commercial premises, the accident prevention regulations of the Association of 

Industrial Professional Associations with respect to electrical systems and operating 

equipment must be observed.

 

•   In schools, training centres, Hobby and DIY workshops, the handling of measuring 

appliances must be responsibly supervised by trained personnel.

 

•   The device may only be operated in a closed, dry room. The space may not become 

damp or wet as this poses a risk of electrocution!

 

•   The product must not be subjected to heavy mechanical stress or intense vibration.

 

•   The product must not be exposed to electromagnetic fields, static electrical fields, 

extreme temperatures, direct sunlight or dampness.

VERSION 07/15