Name
Value
Command
MARKCONTROLsignal[switch[polarity[timebias
[timeguard]]]]
Example
MARKCONTROL MARK1 ENABLE POSITIVE 500 100
Function
Parameter
Description
Switch
Polarity
Timebias
timeguard
Controls processing of mark inputs
ENABLE or DISABLE
POSITIVE or NEGATIVE
An offset, unit is ns, to be applied to the time the mark pulse
is input.
A time period, unit is ms, during which no response to the
input pulses.
2.2.11
NMEATALKER
This command is for NMEA talker configuration. Tersus GNSS systems can output
NMEA0183 format, RTCM2.X/3.2 format and its own observation format.
Table 14 Change the NMEA talker during NMEA output
Name
Value
Command
Nmeatalker id
Example
Nmeatalker GP
Function
change nmeatalker
Parameter description
id GP/AUTO
2.2.12
PPSCONTROL
This command is used to control the polarity, period and pulse width of the PPS
output signal, the unit of period is second, is microseconds for pulse width.
Table 15 PPSCONTROL
Name
Value
Command
PPSCONTROL [switch [polarity [period [pulse width]]]]
Example
PPSCONTROL enable negative 1.0 2000
Function
Control the polarity, period and pulse width of the PPS
signal.
2.2.13
POSAVE
This command implements position averaging for base stations. Position averaging