MALFUNCTIONS AND TROUBLESHOOTING
31
PROBLEM
REASON
SOLUTION
Inefficient burning in the
burning chamber.
- Inefficient shaft draught
- Get your shaft controlled and
have it cleaned every year.
- Use high-quality and dry fuel.
No fuel light is on.
- No fuel in the burning chamber.
- Add fuel and turn off the
thermostat and turn it on again.
Digital screen is not working.
The on-off button light of
panel is on.
- The fuse might have blown.
- Replace the fuse.
If the problem is not removed,
contact the authorized service.
Fan is not working.
- The boiler water temperature
might have reached the
thermostat degree selected.
- The boiler may have run out of fuel.
- The limit thermostat might
have increased.
Circulation pump is not
working.
- The system water temperature
may be under 37
°
C.
- The capacitor of the circulation
pump may be broken.
- Wait for the temperature to
increase.
- Contact the technical service.
- Low-calorie non-quality fuel
- Improper fan settings
- The power cable of the fan
may be loosened.
- The boiler shall start operating
after the temperature falls
from
the thermostat degree selected.
4
°
C
- Add some fuel.
- Reset the limit thermostat.
- Check the electrical connection.
- The circulation pump may be
blocked.
- The electronic card may be broken.
H E A T I N G S Y S T E M S
Summary of Contents for EKY 100
Page 4: ...EKY 17 100 TECHNICAL SPECIFICATIONS 1 H E A T I N G S Y S T E M S D C G F E EKY 17 SIDE VIEW ...
Page 6: ...EKY 125 250 TECHNICAL SPECIFICATIONS 3 H E A T I N G S Y S T E M S 338 mm 365 mm ...
Page 8: ...EKY 125 500 3 BAR TECHNICAL SPECIFICATIONS 5 H E A T I N G S Y S T E M S ...
Page 10: ...EKY 125 1000 5 BAR TECHNICAL SPECIFICATIONS CHART 7 H E A T I N G S Y S T E M S ...
Page 35: ......
Page 36: ...H E A T I N G S Y S T E M S ...