![Termodinamik EKY 100 Installation And Usage Manual Download Page 29](http://html.mh-extra.com/html/termodinamik/eky-100/eky-100_installation-and-usage-manual_1089223029.webp)
USE OF THE BOILER:
26
1.
Fully open the shaft valve before operating the boiler.
2.
Make sure that the system is full of water and the air in the system is removed before
operation. The system should be slowly supplied with water to prevent air formation in the system.
3.
The system should be supplied with water until water comes out of the messenger pipe for
the systems with open expansion tank.
4.
After the system is filled with water, the system should be removed from air and it should
be inspected for any possible leakages.
5.
In the systems with open expansion tank, the base pressure level on the hydrometer should
be marked.
6.
The user of the boiler should be informed on the boiler settings, operation of the boiler and
what to do in case of emergencies.
7.
Place the fuel on the sieves as shown in the burning instructions which is provided with the
boiler. Place igniting materials such as pieces of wood, firewood, etc. on the fuel to light it
manually and close the feeding lid. Leave the lower lid open and do not turn the fan on until
the coal catches fire. After it catches fire, close the lower lid and turn on the fan at low speed.
In the first operation, a thick smoking may be experienced. In this case, turn down the fan air
rate from the setting button on the panel in order to prevent soot.
8.
The circulation pumps should be checked whether they operate or not. The circulation
pump shall not automatically start working until the temperature reaches 37
°
C. This
parameter is set this way in order to prevent the water vapor from condensing and damaging
the boiler by means of heating the boiler as soon as possible.
9.
The boiler water temperature may fall down since the pump shall be reactivated. You may
observe the activation of the pump and the fan looking at the red (led) lights on the digital
indicator.
10.
After the normal burning starts in the boiler and the system is activated, the fan continues
operating until the system water temperature reaches the desired value.
If you turn on the temperature set button on the mechanical control panel or press the
temperature set button on the digital panel, you can set the temperature as desired on the
digital screen where the boiler water temperature is displayed
.
11.
Do not open the feeding lid when the fan is operating.
12.
Note that the quality of the fuel you shall use shall directly affect the efficiency of the
boiler, quality of the burning, amount of ashes and cleaning periods and the amount of bunt
coal. Therefore, we recommend you to buy some amount of sample fuel to check the
performance of the coal before purchasing large amounts.
H E A T I N G S Y S T E M S
Summary of Contents for EKY 100
Page 4: ...EKY 17 100 TECHNICAL SPECIFICATIONS 1 H E A T I N G S Y S T E M S D C G F E EKY 17 SIDE VIEW ...
Page 6: ...EKY 125 250 TECHNICAL SPECIFICATIONS 3 H E A T I N G S Y S T E M S 338 mm 365 mm ...
Page 8: ...EKY 125 500 3 BAR TECHNICAL SPECIFICATIONS 5 H E A T I N G S Y S T E M S ...
Page 10: ...EKY 125 1000 5 BAR TECHNICAL SPECIFICATIONS CHART 7 H E A T I N G S Y S T E M S ...
Page 35: ......
Page 36: ...H E A T I N G S Y S T E M S ...