OVERHEAT:
If the temperature of the boiler is above 95°C, this error occurs; the
appliance stops operating and gives out a signal. This error may result from a malfunction in
the heat sensor. There can be a problem in the pump engine.
PROBE ERROR:
In case the heat sensor of the boiler malfunctions, this error occurs and
the appliance stops operating. This error can result from a malfunction in the heat sensor.
NO FUEL:
When the boiler cools down not being able to keep the temperature steady after
it is heated, the appliance gives out this error and is stops working. This error can result from
a malfunction in the heat sensor. The appliance might have run out of fuel. The fan may have
stopped blowing air.
ROOM THERMOSTAT:
When the room thermostat is on, this warning shall appear on
the screen.
LIMIT THERMOSTAT ERROR – RESET THE LIMIT THERMOSTAT:
There is a
limit thermostat located on the back lid of the appliance box. This thermostat starts working
when the boiler is overheated (generally 95°C is selected) and deactivates the fan and the
reducer. At the same time, it activates the Pump engine.
In this condition, which is expressed as the “thermostat blew”, LIMIT THERMOSTAT
ERROR – RESET THE LIMIT THERMOSTAT error is displayed on the screen.
The boiler needs to cool down for the solution of the limit thermostat problem. When the
temperature of the boiler decreases under 95C (+/-10 degrees), the limit thermostat recovers
from the error yet its contact do not change their positions. In order for the contacts to change
their positions, turn the lid of the limit thermostat and open it. Press the red button you see
when you open the lid. This way, you reset the limit thermostat.
The appliance is reset via ON/OFF button. This way, the error is removed from the screen.
7. ERROR CODES AND SOLUTIONS
20
8. RESTORE THE FACTORY SETTINGS
In order to restore the factory settings of the appliance parameters;
Press the ENTER button and supply the appliance with power.
You will be required to enter a password. Enter the password as “30”. Confirm with
ENTER.
The appliance will require confirmation as “YES / NO”. Select “YES” with up and down
arrow keys and then confirm with ENTER.
The Appliance Parameter settings shall be restored to the factory settings.
The Factory Settings are as follows;
1. Language Selection :
Turkish:0
2.Fan Mode
:
DIMMER :0
3.Pump Opening Temperature
:
37 degrees
4.Pump Closing Temperature
:
32 degrees
5.Air Relay Pre-temperature
:
60 degrees
6.Limit Thermostat Error:
YES
H E A T I N G S Y S T E M S
Summary of Contents for EKY 100
Page 4: ...EKY 17 100 TECHNICAL SPECIFICATIONS 1 H E A T I N G S Y S T E M S D C G F E EKY 17 SIDE VIEW ...
Page 6: ...EKY 125 250 TECHNICAL SPECIFICATIONS 3 H E A T I N G S Y S T E M S 338 mm 365 mm ...
Page 8: ...EKY 125 500 3 BAR TECHNICAL SPECIFICATIONS 5 H E A T I N G S Y S T E M S ...
Page 10: ...EKY 125 1000 5 BAR TECHNICAL SPECIFICATIONS CHART 7 H E A T I N G S Y S T E M S ...
Page 35: ......
Page 36: ...H E A T I N G S Y S T E M S ...