77
EN
TECHNICAL INFORMATION
— Operating voltage when in use: 230 V ±10% 50 Hz.
— Switch: approved cycle 10,000.
— Heating standby mode consumption: <1 W.
Integrated tangencial blower and PTC cartridge:
— Built-in anti-overheating safety device (Overheating
protection by bimetal TCO and thermal fuse).
— PTC heating resistance with self-adaptive power of
850 W to 1000 W max. according to environment.
— Relay.
Class II immersion heater:
— Maximum power of 1500 W, resistive load.
— Relays and triac control device at zero cross voltage
(triac protected by a thermal fuse).
Power supply cable:
— Class II, 3-wire, 800 mm
Environment:
— IP24 (blower horizontal oriented following installation).
— Class II,
— Operating temperature: 0°C to +40°C.
— Storage temperature: -20°C to +65°C.
— Comfort temperature setpoint: b7°C and
+30°C approximately.
— 6-order pilot wire.
Applicable directives and standards after integration of the
module on the finished appliance (under the responsability of
the integrator):
— RED 2014/53/EU:
Article 3.1a (Safety): EN60335-1/EN60335-2-30/EN60335-
2-43/ EN62233
Article 3.1b (EMC): ETSI EN301489-1/ ETSI EN301489-3
Article 3.2 (RF): ETSI EN 300440
— ERP 2009/125/EC
— Regulation 2015/1188/EU
— ROHS 2011/65/EU : EN50581
The module is manufactured using processes which are
certified ISO 9001 V2015.