61
EN
USER SETTINGS
ACCESS
To access the User settings in 3 steps, enter the Auto, Comfort, Eco or Frost protection mode, then:
Information display
Information display
User
= réglages utilisateur
Press for 5
seconds
1
Press briefly
twice
2
Press briefly
3
1
1
Setting sequence:
Backlighting
→
Eco mode temperature lowering-level
→
Frost protection temperature
→
Super comfort
→
Comfort
setting temperature limit
→
Maximal Boost duration
→
Maximum ambient temperature
→
Temperature unit.
BACKLIGHT SETTING
①
Three modes can be set:
L1
= Temporary backlighting: Backlight of the display
when a button is pressed or during presence
detection.
L2
= Non-stop backlighting: Backlight of the display
all the time.
L3
= Temporary backlighting: Backlight of the display
when a button is pressed.
L3 mode is the default setting.
Press
or
to choose the setting you require.
②
Press
to save and move to the next setting.
To exit the user settings, press
twice.
SETTING THE ECO MODE
TEMPERATURE LOWERING-LEVEL
The drop in temperature is set at -3.5°C compared to the
set temperature of the Comfort mode. You can adjust the
lowered level from -1°C to -8°C, by intervals of 0.5°C.
Important:
whatever the lowering level set, the Eco setting
temperature will never exceed 19°C.