71
EN
②
To save and move automatically to the next setting
press
.
③
To exit the Expert settings, press
3 times.
INTERNAL TEMPERATURE
MONITORING
An integrated overheating safety is present on our blower.
It is activated when an internal temperature limit is reached:
the blower and its controller will stop immediately.
The maximum setting is preset to 65°C. You can adjust
from 60°C to 90°C by intervals of 5°C.
Press
or
then save by pressing
.
If you do not want to change it, press
: the device
changes automatically to set the next setting.
1
2
To exit the Expert settings, press
3 times.
RESTORING FACTORY SETTINGS
If the PIN code protection is disabled, the user, installer
and expert settings are re-initialized:
①
From the internal temperature monitoring setting,
press
.
rest
appears on the display.
②
NO
appears. Press
or
to select
YES
.
yes
= Factory settings reset
NO
= Factory settings not reset
③
Press the key
for 5 seconds. The device returns
to its initial configuration and goes back automatically
to the Auto mode.