Operator's Manual
Work Area Safety
Part No. 1297932GT
Z
®
-30/20N • Z
®
-30/20N RJ
13
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Voltage
Phase to Phase
Minimum Safe
Approach Distance
0 to 300V
Avoid Contact
300V to 50KV
10 ft
3.05 m
50KV to 200KV
15 ft
4.60 m
200KV to 350KV
20 ft
6.10 m
350KV to 500KV
25 ft
7.62 m
500KV to 750KV
35 ft
10.67 m
750KV to 1000KV
45 ft
13.72 m
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
500 lbs
227 kg
Machine equipped with Aircraft
Protection Package
440 lbs
200 kg
Maximum occupants
2
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will
reduce the rated platform capacity and must be
subtracted from the platform capacity. See the
decals with the options and accessories.
Do not raise or extend the
boom unless the machine
is on a firm, level surface.
Do not depend on the tilt alarm as a level indicator.
The tilt alarm sounds in the platform only when the
machine is on a severe slope.