Service and Repair Manual
March 2018
Deutz D 2.9 L4 Engine Fault Codes
102
S®-
80 • S®
-85
• S®
-80X
Part No. 1269074GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI
KWP
Description
654 3
583
Injector 4 (in firing order); short
circuit
654 4
589
High side to low side short circuit
in the injector 4 (in firing order)
654 5
571
Injector 4 (in firing order);
interruption of electric connection
676 11
543
Cold start aid relay error.
676 11
544
Cold start aid relay open load
677 3
956
Starter relay high side; short
circuit to battery
677 3
960
Starter relay low side; short
circuit to battery
677 4
957
Starter relay high side; short
circuit to ground
677 4
961
Starter relay low side; short
circuit to ground
677 5
958
Starter relay; no load error
677 12
959
Starter relay; powerstage over
temperature
703 3
426
Engine running lamp; short circuit
to battery
703 4
427
Engine running lamp; short circuit
to ground
703 5
424
Engine running lamp; open load
703 12
425
Engine running lamp;
powerstage over temperature
729 5
545
Cold start aid relay open load
729 12
547
Cold start aid relay; over
temperature error
898 9
305
Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
1079 13
946
Sensor supply voltage monitor 1
error (ECU)
1080 13
947
Sensor supply voltage monitor 2
error (ECU)
SPN
FMI
KWP
Description
1109 2
121
Engine shut off demand ignored
1136 0
1398
Physikal range check high for
ECU temperature
1136 1
1399
Physikal range check low for
ECU temperature
1136 3
1400
Sensor error ECU temperature;
signal range check high
1136 4
1401
Sensor error ECU temperature;
signal range check low
1176 3
849
Sensor error pressure sensor
upstream turbine; signal range
check high
1176 4
850
Sensor error pressure sensor
downstream turbine; signal range
check high
1180 0
1193
Physical range check high for
exhaust gas temperature
upstream turbine
1180 0
1460
Turbocharger Wastegate CAN
feedback; warning threshold
exceeded
1180 0
1462
Exhaust gas temperature
upstream turbine; warning
threshold exceeded
1180 1
1194
Physical range check low for
exhaust gas temperature
upstream turbine
1180 1
1461
Turbocharger Wastegate CAN
feedback; shut off threshold
exceeded
1180 1
1463
Exhaust gas temperature
upstream turbine; shut off
threshold exceeded
1180 3
1067
Sensor error exhaust gas
temperature upstream turbine;
signal range check high
1180 11
1066
Sensor exhaust gas temperature
upstream turbine; plausibility
error
1188 2
1414
Wastegate; status message from
ECU missing
Summary of Contents for Genie S-80
Page 14: ......
Page 73: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 59 ...
Page 83: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 69 ...
Page 141: ...March 2018 Service and Repair Manual 127 Continental TME27 Engine Harness ...
Page 144: ...Service and Repair Manual March 2018 130 S 80X Ground Control Box Wiring Diagram ...
Page 145: ...March 2018 Service and Repair Manual 131 Deutz TD2 9 L4 Engine Harness ...
Page 148: ...Service and Repair Manual March 2018 134 Perkins 404F 22T Engine Harness ...
Page 285: ...March 2018 Service and Repair Manual 271 Continental Options Schematic ...
Page 288: ...Service and Repair Manual March 2018 274 Deutz and Perkins Options Schematic ...
Page 289: ...March 2018 Service and Repair Manual 275 Platform Level Cutout CTE Option ...
Page 292: ...Service and Repair Manual March 2018 278 12 kW Hydraulic Generator Wiring Diagram ...
Page 293: ...March 2018 Service and Repair Manual 279 12 kW Hydraulic Generator Electrical Schematic ...
Page 296: ...Service and Repair Manual March 2018 282 Belt Driven Generator Option ...
Page 297: ...March 2018 Service and Repair Manual 283 Hydraulic Schematic 2WD Models ...
Page 301: ......