Service and Repair Manual
March 2018
Specifi
cations
2
S®-
80 • S®
-85
• S®
-80X
Part No. 1269074GT
Performance Specifications
Drive speed, maximum
Stowed position,
RT tires
40 ft / 7.9 - 8.5 sec
12.2 m / 7.9 - 8.5 sec
Stowed position,
High Flotation tires
40 ft / 11 - 13 sec
12.2 m / 11 - 13 sec
Raised or Extended
40 ft / 40 - 45 sec
12.2 m / 40 - 45 sec
Braking distance, maximum
High range on paved surface
6 ft / 1.8 m
Gradeability
Refer to Operator's Manual
Boom function speeds, maximum from platform
controls
Jib Boom up (S-85)
25 - 35 sec
Jib Boom down (S-85)
15 - 25 sec
Boom up (ANSI, CSA, models)
57 - 65 sec
Boom up (CE, AS models)
75 - 83 sec
Boom down (ANSI, CSA, models)
61 - 69 sec
Boom down (CE, AS models)
75 - 83 sec
Boom extend
59 - 67 sec
Boom retract
57 - 65 sec
Turntable rotate, (360°) fully stowed
95 - 103 sec
Turntable rotate, (360°) boom raised
or extended
210 - 250 sec
Platform rotate, 160°
8 - 12 sec
Platform level (10° range of motion)
ANSI, CSA
3 - 5 sec
Platform level (10° range of motion)
CE, AS
20 - 22 sec
For operational specifications, refer to the
Operator's Manual.
Hydraulic Oil Specifications
Hydraulic Fluid Specifications
Genie specifications require hydraulic oils which are
designed to give maximum protection to hydraulic
systems, have the ability to perform over a wide
temperature range, and the viscosity index should
exceed 140. They should provide excellent antiwear,
oxidation prevention, corrosion inhibition, seal
conditioning, and foam and aeration suppression
properties.
Cleanliness level,
minimum
ISO 15/13
Water content,
maximum
250 ppm
Recommended Hydraulic Fluid
Hydraulic oil type
Chevron Rando HD Premium
Viscosity grade
32
Viscosity index
200
Optional Hydraulic Fluids
Mineral based
Shell Tellus S2 V 32
Shell Tellus S2 V 46
Shell Tellus S4 VX 32 Shell
Shell Donax TG (Dexron III)
Chevron 5606A
Biodegradable
Petro Canada Environ MV 46
Fire resistant
UCON Hydrolube HP-5046
Note: Genie specifications require additional
equipment and special installation instructions for
the approved optional fluids. Consult Genie
Product Support before use.
Optional fluids may not have
the same hydraulic lifespan and
may result in component
damage.
Note: Extended machine operation can cause the
hydraulic fluid temperature to increase beyond it's
maximum allowable range. If the hydraulic fluid
temperature consistently exceeds 200°F / 90°C an
optional oil cooler may be required.
Summary of Contents for Genie S-80
Page 14: ......
Page 73: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 59 ...
Page 83: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 69 ...
Page 141: ...March 2018 Service and Repair Manual 127 Continental TME27 Engine Harness ...
Page 144: ...Service and Repair Manual March 2018 130 S 80X Ground Control Box Wiring Diagram ...
Page 145: ...March 2018 Service and Repair Manual 131 Deutz TD2 9 L4 Engine Harness ...
Page 148: ...Service and Repair Manual March 2018 134 Perkins 404F 22T Engine Harness ...
Page 285: ...March 2018 Service and Repair Manual 271 Continental Options Schematic ...
Page 288: ...Service and Repair Manual March 2018 274 Deutz and Perkins Options Schematic ...
Page 289: ...March 2018 Service and Repair Manual 275 Platform Level Cutout CTE Option ...
Page 292: ...Service and Repair Manual March 2018 278 12 kW Hydraulic Generator Wiring Diagram ...
Page 293: ...March 2018 Service and Repair Manual 279 12 kW Hydraulic Generator Electrical Schematic ...
Page 296: ...Service and Repair Manual March 2018 282 Belt Driven Generator Option ...
Page 297: ...March 2018 Service and Repair Manual 283 Hydraulic Schematic 2WD Models ...
Page 301: ......