Service and Repair Manual
March 2018
Control System Fault Codes
92
S®-
80 • S®
-85
• S®
-80X
Part No. 1269074GT
Error Source
Error Type
Condition
Solution
ID
Name
ID
Name
32 Secondary Up /
Down. Directional
Valves
21
Fault
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds.
Power up controller with
problem corrected.
33 Secondary Up /
Down Flow Valve
12
Value Too High Limited Speed and Direction frozen at
zero and neutral, Alarm sounds.
Power up controller with
problem corrected.
15
Value Too Low
17
Not calibrated
Normal function except threshold for
one or both directions is zero.
Calibrate valve threshold.
34 primary Boom
Extend / Retract
Limit Switches
31
Invalid setup
Initiate 1 -second beep of Alarm.
1000lb. Mode: Required retract into
FULLY RETRACTED state before
lowering.
500lb. Mode: Operates normally.
Dual capacity models.
Fully retract, then lower
boom.
Check and service ext/ret
and fully stowed switches.
41 Turntable Rotate
Joystick
11
Value at 5.0 V
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds.
Power up controller with
problem corrected.
12
Value Too High
15
Value Too Low
16
Value at 0 V
17
Not calibrated
Initiate 1 -second beep of Alarm.
Calibrate Joystick.
42 Turntable Rotate
Directional Valves
21
Fault
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds.
Power up controller with
problem corrected.
17
Not calibrated
Normal function except threshold for
one or both directions is zero.
Calibrate valve threshold.
43 Turntable Rotate
Flow Valve
12
Value Too High Limited Speed and Direction frozen at
zero and neutral, Alarm sounds.
Power up controller with
problem corrected.
15
Value Too Low
17
Not calibrated
Normal function except threshold for
one or the other direction is zero.
Display message on LCD.
Calibrate valve threshold.
44 Drive Enable
Override Switch
21
Fault
Drive enable override direction is
frozen at neutral.
Power up controller with
problem corrected.
45 Platform Level
Switch
21
Fault
Platform level frozen at neutral.
Power up controller with
problem corrected.
46 Primary Extend /
Retract Switch
21
Fault
Platform Extend / Retract frozen at
neutral.
Power up controller with
problem corrected.
Summary of Contents for Genie S-80
Page 14: ......
Page 73: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 59 ...
Page 83: ...March 2018 Service and Repair Manual Manifolds Part No 1269074GT S 80 S 85 S 80X 69 ...
Page 141: ...March 2018 Service and Repair Manual 127 Continental TME27 Engine Harness ...
Page 144: ...Service and Repair Manual March 2018 130 S 80X Ground Control Box Wiring Diagram ...
Page 145: ...March 2018 Service and Repair Manual 131 Deutz TD2 9 L4 Engine Harness ...
Page 148: ...Service and Repair Manual March 2018 134 Perkins 404F 22T Engine Harness ...
Page 285: ...March 2018 Service and Repair Manual 271 Continental Options Schematic ...
Page 288: ...Service and Repair Manual March 2018 274 Deutz and Perkins Options Schematic ...
Page 289: ...March 2018 Service and Repair Manual 275 Platform Level Cutout CTE Option ...
Page 292: ...Service and Repair Manual March 2018 278 12 kW Hydraulic Generator Wiring Diagram ...
Page 293: ...March 2018 Service and Repair Manual 279 12 kW Hydraulic Generator Electrical Schematic ...
Page 296: ...Service and Repair Manual March 2018 282 Belt Driven Generator Option ...
Page 297: ...March 2018 Service and Repair Manual 283 Hydraulic Schematic 2WD Models ...
Page 301: ......