TCW241_R4.17
–
October 2022
Page 33
setup -> io -> virtualSetup -> virtual4setup
OID
Name
Access
Description
Syntax
x.3.2.2.5.4.1.0
virtualInput4description
read-write
Virtual input 4 description
DisplayString
x.3.2.2.5.4.2.0
virtualInput4max
read-write
Virtual input 4 maximum
Integer32
x.3.2.2.5.4.3.0
virtualInput4min
read-write
Virtual input 4 minimum
Integer32
x.3.2.2.5.4.4.0
virtualInput4hyst
read-write
Virtual input 4 hysteresis
Integer32
x.3.2.2.5.4.5.0
virtualInput4Parent
read-write
Virtual input 4 parent
INTEGER{
none(0),sensor11(1),se
nsor21(2),sensor31(3),s
ensor41(4),sensor51(5),
sensor61(6),sensor71(7
),sensor81(8),sensor12(
9),sensor22(10),sensor
32(11),sensor42(12),se
nsor52(13),sensor62(14
),sensor72(15),sensor8
2(16),analog1(17),analo
g2(18),analog3(19),anal
og4(20)
}
monitorNcontrol -> sensors -> sensor1
OID
Name
Access
Description
Syntax
x.3.3.1.1.1.0
s11Int
read-only
S11 value x1000 in Integer format
Integer32
x.3.3.1.1.2.0
s12Int
read-only
S12 value x1000 in Integer format
Integer32
x.3.3.1.1.3.0
s1ID
read-only
S1 ID value
Mac Address
monitorNcontrol -> sensors -> sensor2
OID
Name
Access
Description
Syntax
x.3.3.1.2.1.0
s21Int
read-only
S21 value x1000 in Integer format
Integer32
x.3.3.1.2.2.0
s22Int
read-only
S22 value x1000 in Integer format
Integer32
x.3.3.1.2.3.0
s2ID
read-only
S2 ID value
OCTET STRING (SIZE
(16))
monitorNcontrol -> sensors -> sensor3
OID
Name
Access
Description
Syntax
x.3.3.1.3.1.0
s31Int
read-only
S31 value x1000 in Integer format
Integer32
x.3.3.1.3.2.0
s32Int
read-only
S32 value x1000 in Integer format
Integer32
x.3.3.1.3.3.0
s3ID
read-only
S3 ID value
OCTET STRING (SIZE
(16))
monitorNcontrol -> sensors -> sensor4
OID
Name
Access
Description
Syntax
x.3.3.1.4.1.0
s41Int
read-only
S41 value x1000 in Integer format
Integer32
x.3.3.1.4.2.0
s42Int
read-only
S42 value x1000 in Integer format
Integer32
x.3.3.1.4.3.0
s4ID
read-only
S4 ID value
OCTET STRING (SIZE
(16))
monitorNcontrol -> sensors -> sensor5
OID
Name
Access
Description
Syntax
x.3.3.1.5.1.0
s51Int
read-only
S51 value x1000 in Integer format
Integer32
x.3.3.1.5.2.0
s52Int
read-only
S52 value x1000 in Integer format
Integer32
x.3.3.1.5.3.0
s5ID
read-only
S5 ID value
OCTET STRING (SIZE
(16))
monitorNcontrol -> sensors -> sensor6
OID
Name
Access
Description
Syntax
x.3.3.1.6.1.0
s61Int
read-only
S61 value x1000 in Integer format
Integer32
x.3.3.1.6.2.0
s62Int
read-only
S62 value x1000 in Integer format
Integer32
x.3.3.1.6.3.0
s6ID
read-only
S6 ID value
OCTET STRING (SIZE
(16))