![TER SRL Multi Synergic 280 Instruction Manual Download Page 54](http://html1.mh-extra.com/html/ter-srl/multi-synergic-280/multi-synergic-280_instruction-manual_1088149054.webp)
Instruction Manual
Multi Synergic 280 - Multi Synergic 350 - Multi Synergic 400F - Multi Synergic 500- Multi Synergic 500F and Accessories
54
Default icon Iset is on
Rotate K1 for adjust set current, or
use wire speed setting.
Push K1 until icon ser speed L1 is on.
Rotate K1 for adjust wire speed.
Display-1 show the wire speed in mt/min.
Default icon Arc Lenght set (L12)
is on.
Rotate knob K2 for adjust the set-
ting of lenght arc.
Display-2 show the set arc lenght.
Push knob K2 until the icon Induc-
tance (L14) is on. Rotate K2 for
adjust the inductance setting.
Display-2 show the set inductance.
The display return to show the
default setting value 5 seconds after
last adjustment
K2
Push knob K2 until the icon
Thickness setting (L13) is on.
Rotate K2 for adjust the thickness.
Display-2 show the set of value.
The display return to show the de-
fault setting value 5 seconds after
last adjustment .
Current Setting - PULSE MIG mode
PULSE MIG MODE: PARAMETER SETTING
Wire Speed Setting - PULSE MIG mode
Arc Lenght Setting - PULSE MIG mode
Inductance Setting - PULSE MIG mode
Thickness Setting - PULSE MIG mode
K1
K1
K2
K2