Default icon Arc Lenght set (L12)
is on.
Rotate knob K2 for adjust the set-
ting of lenght arc.
Display-2 show the set arc lenght.
Push knob K2 until icon CYCLE
(L15) is ON.
Rotate K2 for select the torch
switch Cycle.
Set 2T cycle with
icon L16 is on.
Set 2T slope cycle
with icon L16 and
L18 are on.
Set 4T cycle with
icon L17 is on.
Set 4T slope cycle
with icon L17 and
L18 are on.
Timer cycle with
icon L19 is on.
Default icon Iset is on
Rotate K1 for adjust set current, or
use wire speed setting.
Push K1 until icon ser speed L1 is on.
Rotate K1 for adjust wire speed.
Display-1 show the wire speed in mt/min.
Select the Torch switch cycle - Manual MIG mode
SYNERGIC MIG MODE : PARAMETER SETTING
Current Setting- Synergic MIG mode
Wire Speed Setting - Synergic MIG mode
Arc Lenght Setting - Synergic MIG mode
K2
K2
K2
K2
K2
K2
K2
K1
K1