background image

9. Mount Thermostat & Battery Installation

Important:

Then it will be working.

You can choose traditiona mode or heat pump mode based on your requirements. When heat pump mode 

is set, the compressor will have a 5 minute delay before restarting.

You can choose to have reversing valve on the heat pump work in the heat mode or the cool mode.

In the heat pump mode, please check the recersing valve to see whether it is in O or B position, and 

enter the system to set teversing valve to the position you need. 

The thermostat has an intelligent recovery function that brings your room to temperature at exactly the

pre-set time by turning on the Heating earlier. Select 1 to activate the intelligent recover function, Select

0 to deactivate the intelligent recovery function. The default setting is “0”.

This function is the control and selection for the heat fan, If you use a gas or oil heating system, Please 

choose “

GAS

” (system controls fan operation). If you use an eletric heating system, please choose 

Electric

” (thermostat controls fan operation).

High quality alkaline batteries are recommended. Rechargeable batteries or low quality batteries 

may not have a 1-year life span.

Step 1: Align the inner snaps with 

the top part of the thermostat.

Step 2: Hang the two hooks of the

front part at 30°right to the snaps.

Step 3: Press in the lower part of the front

display panel to complete the installation.

TENZA

TENZA

Summary of Contents for CPT10

Page 1: ...te control systems Please read this manual carefully before installation to ensure proper function and that you take advantage of the many features of this programmable thermostat 2 Production Functions Overview 2 1 Applications 2 2 Features 1 When the temperature is outside the display range the words HI or LO will be shown on the display instead of a number If the temperature higher than the dis...

Page 2: ...tem Cool Symbol When the System Cool symbol is displayed it indicates the thermostat is in cooling mode System Heat Symbol When the System Heat symbol is displayed it indicates the thermostat is in heating mode TENZA Down button In heating cooling mode the Down button lowers the temperature setting When programming the Down button will be used for changing system parameters Up button In heating co...

Page 3: ...the location should be representative of the building 5 Thermostat Base Installation Caution Equipment Damage Hazard The thermoatat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulation Insert a screwdriver into the slot and pry up the front part of the panel to open it For horizontal mount put one screw left in the left hole...

Page 4: ...at pump mode please check the reversing valve to see whether it is in O or B position and enter the system to set reversing valve to the position required The system is in the electric mode as default setting If the system is gas or oil enter the setting interface in the gas mode For 24 VAC common connection when thermostat is used with battery power mode Do not over tighten terminal block screws ...

Page 5: ...s to set the system clock And if you hold or the adjudtment will be accelerated 2 Press SET again to set the day the week When the week area is flashing press or to change the day the week 3 Press SET again to set wake time from Monday to Friday When the clock area is flashing press or to adjust the time 4 Press SET again to set Wake temperature from Monday to Friday When the clock area is flashin...

Page 6: ...ctly the pre set time by turning on the Heating earlier Select 1 to activate the intelligent recover function Select 0 to deactivate the intelligent recovery function The default setting is 0 This function is the control and selection for the heat fan If you use a gas or oil heating system Please choose GAS system controls fan operation If you use an eletric heating system please choose Electric t...