Run button: Once programming parameters have been set for time and function, 

use the Run button to save and exit the programming interface. Press the Run 

button once to run the time program that has been set. 

Hold/Set button: Press the Hold/Set button once and the thermostat will stay in the 

current mode and temperature setting. In heating/cooling mode, pressing the Hold/Set 

button will hold the temperature that it is currently set at and will not change during 

the setting process. In the heating/cooling mode, pressing and holding the Hold/Set 

button for 3 seconds allows you to enter the programming parameter interface. When 

thermostat is Off, pressing and holding the Hold/Set button for 5 seconds allows you 

to enter the programming parameter interface.

Clock and day of the Week Display.

Cool symbol: When the Cool symbol is displayed, the cooling relay has been activated.

When the Cooling symbol is flashing, it means that the cooling relay is in the set-up 

delay process.

Heat Symbol: When the Heating symbol is displayed,the heating relay has been

activated. When the Heating symbol is flashing, it means that the heating relay is in the

set-up delay process.

System Cool Symbol: When the System Cool symbol is displayed, it indicates the

thermostat is in cooling mode.
System Heat Symbol: When the System Heat symbol is displayed, it indicates the 

thermostat is in heating mode.

TENZA

Down button: In heating/cooling mode, the Down button lowers the temperature

setting. When programming, the Down button will be used for changing system

parameters.

Up button: In heating/cooling mode, the Up button raises the temperature setting. 

When programming, the Up button will also be used for changing system 

parameters.
Cool/Heat/Off button: Press once for Cooling Mode. Press twice for Heating Mode.

Press 3 times to turn Off the thermostat.

Fan button: Switches between fan On and Auto. When fan is On, the fan on your

appliance will remain on. In Auto mode the fan will come on only when heating or 

cooling.

Hold symbol: When the Hold symbol is displayed, the Hold button has been activated 

and the current temperature will be held and the thermostat will not follow programmed 

routine.
Room Temperature Display: Displays the current room temperature.

Temperature Setting Display: Displays the current temperature setting.

Low Battery Warning: When this symbol is displayed replace the batteries with 2 new,

high quality AA batteries.

Fan Symbol: Displays the current mode of the fan.
Program Setting Display: Indicates when the system is in the setting process.

Summary of Contents for CPT10

Page 1: ...te control systems Please read this manual carefully before installation to ensure proper function and that you take advantage of the many features of this programmable thermostat 2 Production Functions Overview 2 1 Applications 2 2 Features 1 When the temperature is outside the display range the words HI or LO will be shown on the display instead of a number If the temperature higher than the dis...

Page 2: ...tem Cool Symbol When the System Cool symbol is displayed it indicates the thermostat is in cooling mode System Heat Symbol When the System Heat symbol is displayed it indicates the thermostat is in heating mode TENZA Down button In heating cooling mode the Down button lowers the temperature setting When programming the Down button will be used for changing system parameters Up button In heating co...

Page 3: ...the location should be representative of the building 5 Thermostat Base Installation Caution Equipment Damage Hazard The thermoatat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulation Insert a screwdriver into the slot and pry up the front part of the panel to open it For horizontal mount put one screw left in the left hole...

Page 4: ...at pump mode please check the reversing valve to see whether it is in O or B position and enter the system to set reversing valve to the position required The system is in the electric mode as default setting If the system is gas or oil enter the setting interface in the gas mode For 24 VAC common connection when thermostat is used with battery power mode Do not over tighten terminal block screws ...

Page 5: ...s to set the system clock And if you hold or the adjudtment will be accelerated 2 Press SET again to set the day the week When the week area is flashing press or to change the day the week 3 Press SET again to set wake time from Monday to Friday When the clock area is flashing press or to adjust the time 4 Press SET again to set Wake temperature from Monday to Friday When the clock area is flashin...

Page 6: ...ctly the pre set time by turning on the Heating earlier Select 1 to activate the intelligent recover function Select 0 to deactivate the intelligent recovery function The default setting is 0 This function is the control and selection for the heat fan If you use a gas or oil heating system Please choose GAS system controls fan operation If you use an eletric heating system please choose Electric t...