background image

(1) COOL/HEAT/OFF: Press the “COOL/HEAT/OFF” button once to turn on the system. The mode will be

cool and “      ” is displayed. The room temperature

 

setting temperature, and clock will be also displayed. 

To change to heating mode, press the COOL/HEAT/OFF button a second time and “      ” will be displayed.

Press again to turn off the system and “

off 

” is displayed.

(2) Setting temperature: When power on, press “      ” or “      ” to set the temperature. Press “      ” to lower

the setting temperature, and press “      ” to raise the setting temperature.

(3) Fan mode: When power is on, press the fan butoon to select fan on, and press a second time to change

the fan to auto mode.

(4) Run button: When power on, press the button to run the program that has been set. “Run On” will be 

displayed. In programming mode, or when changing system parameters, press “Run” to exit and save the

changed parametrs.

(5) Hold button: When power on, press the “Hold” button to hold the temperature setting, The program will
not run and the thermostat will display “Hold”. For example: if the setting temperature is 60°F

 

, after 

pressing the “HOLD” the system will lock the setting temperature to 60°F

.

  

If there are no inputs for 30 seconds, the system will automatically exit the setting interface and the 
changed parameters will not be saved. When power on (on cool/heat mode), hold “SET” for 3 
seconds to enter the programing mode:
(1) First is to set the system clock. And if you hold “      ” or “      ”, the  adjudtment will be accelerated.
(2) Press “SET” again to set the day the week. When the week area is flashing, press “      ” or “      ” to 

change the day the week.
(3) Press “SET” again to set wake time from Monday to Friday. When the clock area is flashing, press

“      ” or “      ” to adjust the time.
(4)  Press “SET” again to set Wake temperature from Monday to Friday. When the clock area is flashing,

press “      ” or “      ” to adjust the temperature.
(5) Continuing to press “SET” allows you set the time temperature for Leave, Return and Sleep from Monday

to Friday and Saturday, sunday separately.
(6) After you have finished programming the setting, press “RUN” to exit the setting interface and save the 

programmed parameters. 

21°C/69.8°F

21°C/69.8°F

21°C/69.8°F

21°C/69.8°F

17°C/62.6°F

17°C/62.6°F

17°C/62.6°F

17°C/62.6°F

24°C/75.2°F

24°C/75.2°F

24°C/75.2°F

24°C/75.2°F

28°C/82.4°F

28°C/82.4°F

26°C/78.8°F

26°C/78.8°F

When the power is off, hold the “SET” button for 7 seconds to enter the parameter programming 

interface. 

The Room temperature area will display a symbol for each parameter, and the clock 

area will display the values for each parameter. Continue pressing the “SET” button to cycle 

through each parameter on the display. Press “ UP Button” or “Down Button ” to adjust each 

parameter.  

After you have finished programming, press the “RUN” button to exit the programming 

interface and save the set parameters. (If there are no inputs for 30 seconds, the system will 

automatically exit the setting interface and the changed parameters will not be saved.)

Summary of Contents for CPT10

Page 1: ...te control systems Please read this manual carefully before installation to ensure proper function and that you take advantage of the many features of this programmable thermostat 2 Production Functions Overview 2 1 Applications 2 2 Features 1 When the temperature is outside the display range the words HI or LO will be shown on the display instead of a number If the temperature higher than the dis...

Page 2: ...tem Cool Symbol When the System Cool symbol is displayed it indicates the thermostat is in cooling mode System Heat Symbol When the System Heat symbol is displayed it indicates the thermostat is in heating mode TENZA Down button In heating cooling mode the Down button lowers the temperature setting When programming the Down button will be used for changing system parameters Up button In heating co...

Page 3: ...the location should be representative of the building 5 Thermostat Base Installation Caution Equipment Damage Hazard The thermoatat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulation Insert a screwdriver into the slot and pry up the front part of the panel to open it For horizontal mount put one screw left in the left hole...

Page 4: ...at pump mode please check the reversing valve to see whether it is in O or B position and enter the system to set reversing valve to the position required The system is in the electric mode as default setting If the system is gas or oil enter the setting interface in the gas mode For 24 VAC common connection when thermostat is used with battery power mode Do not over tighten terminal block screws ...

Page 5: ...s to set the system clock And if you hold or the adjudtment will be accelerated 2 Press SET again to set the day the week When the week area is flashing press or to change the day the week 3 Press SET again to set wake time from Monday to Friday When the clock area is flashing press or to adjust the time 4 Press SET again to set Wake temperature from Monday to Friday When the clock area is flashin...

Page 6: ...ctly the pre set time by turning on the Heating earlier Select 1 to activate the intelligent recover function Select 0 to deactivate the intelligent recovery function The default setting is 0 This function is the control and selection for the heat fan If you use a gas or oil heating system Please choose GAS system controls fan operation If you use an eletric heating system please choose Electric t...

Reviews: