MAINTENANCE
365 MM173 (3---90)
3-20
10. After cleaning the air filter element, inspect it for
damage by placing a bright light inside. The
slightest rupture requires replacement of the
filter. Clean and inspect the seals on the ends
of the element. They should be unbroken and
flexible. Remember, the element must be
replaced after it has been cleaned three times.
B
A
03500
INSPECTING AIR FILTER ELEMENT
A. Bright Light
B. Filter Element
11. Install the new or cleaned filter element so the
fins on the element are at the intake end of the
air cleaner. Use care so the fins are not
damaged. Make sure the element is seating
evenly. Tighten the filter wing nut.
12. Install the dust cap with the arrows pointing up.
Tighten the clamp ring to hold it in place.
Check all intake hose connections for leaks or
abrasion.
A
02492
DUST CAP
A. Dust Cap
13. Reset the air filter service indicator.
14. Close the access doors.
Summary of Contents for 365
Page 1: ...r 365 MM173 ...
Page 6: ...ABOUT THIS MANUAL 365 MM173 3 90 d ...
Page 16: ...SPECIFICATIONS 365 MM173 3 90 1 2 ...
Page 20: ...SPECIFICATIONS 365 MM173 3 90 1 6 ...
Page 22: ...OPERATION 365 MM173 3 90 2 2 ...
Page 42: ...OPERATION 365 MM173 3 90 2 22 ...
Page 56: ...MAINTENANCE 365 MM173 3 90 3 14 03767 HYDRAULIC SCHEMATIC ...
Page 98: ...MAINTENANCE 365 MM173 3 90 3 56 ...
Page 100: ...APPENDIX 365 MM 3 90 4 2 ...