TM-12E/13E/13R
EN-4
j).Auto Power Off: The power will be automatically turn
off while the range set is unchanged for more than 30
minutes.
k).Disabling Auto Off: Set the range selector OFF
position to any range and also press down ZERO or
RANGE button.
l).Operating Temperature & Humidity: 5
℃
~ 40
℃
,below
80%RH.
m).Storage Temperature & Humidity: -10
℃
~ 60
℃
,
below 70%RH.
n).Safety: IEC61010 and EN61010 (IEC61010-1,
IEC61010-2-031, IEC61010-2-032) CAT
Ⅲ
600V.
o).EMC:This apparatus was designed in accordance
with EMC standards in force and its compatibility has
been tested in accordance EN61326 (1997) + A1
(1998) + A2 (2001).
p).Dimension: 195mm(L)x64mm(W)x30mm(H).
q).Weight: About 240g.(including batteries)
r).Accessories: Test Leads
、
manual
、
Batteries.
Electrical Specifications:
Accuracy is indicated as [% of r digit number].
It is referred to the following reference conditions: 23°C
± 5°C with RH <75%