12. MAINTENANCE and TROUBLE-SHOOTING  

TENDO Power Analyzer can be cleaned with a soft, damp cloth. Avoid spilling liquid on the 

microcomputer and sensor unit.

Keep the microcomputer out of direct sunlight.

Remove the batteries when storing the Power Analyzer. 

If the microcomputer does not function properly

 - the batteries should be charged.

In addition, make sure that the microcomputer wire is connected to the sensor unit. 

!!! Check the Filter. The value of Filter has to be set less than the amplitude of the motion !!!

For indoor use, only. 

Attention: This product contains magnet. 

Magnet Safety

1. 

Proper Magnet Handling

: Assure that no two magnets come in close proximity to one another 

when handling. 
2. 

Transportation and Storage

: Wood, plastic or other non-ferrous containers can be used to create 

barriers around the magnet for safe transportation or storage. 
3. 

Medical Devices

: Some medical devices (such as pacemakers and heart defibrillators) can be 

adversely affected by strong magnetic fields. 
4. 

Credit Cards and Electronic Devices

: Credit cards, computer disks, and other magnetic storage 

devices away from magnets. Exposure to the magnetic field may result in malfunction or 
permanent damage to such items. 
5. 

Keep away from mechanical watches, compass and hearing aid

 

-

CDs and DVDs sticks are not magnetic data carriers and will therefore not be damaged by static 

magnetic fields. 

-

Cameras, cell phones and smart phones contain non-magnetic storage media. Therefore, static 

magnetic fields near those devices cannot delete data. 

-

USB sticks and memory cards are not magnetic data carriers and will therefore not be damaged 

by static magnetic fields. 

-

A static magnetic field does not damage a vehicle key or the embedded transponder for the anti-

theft device. Therefore, you can hang up your vehicle key on a magnetic board. 

Manufactured in Europe. 

TENDO Sport 
Zlatovska 22 

911 01 Trencin 

Phone / fax : 00421-32-6401500

Slovak Republic 

e-mail: [email protected]

www.tendosport.com

21

Summary of Contents for V- 316

Page 1: ...TENDO Unit YOUR INTELLIGENT WEIGHT TRAINING Hardware User Manual www tendosport com 1...

Page 2: ...tup mode 12 6 4 What can be set up in setting mode 12 6 4 1 Load 12 6 4 2 Audio signal upper lower limits 12 6 4 3 Filter 13 6 4 4 limit for partial average power and peak force 14 6 4 5 Rest time mea...

Page 3: ...the system and give you an idea how to begin What comes as a part of the unit Microcomputer Sensor Unit Data Cable Tripod Rechargeable Batteries 4x of AA size type NiMH Built in Battery Charger AC DC...

Page 4: ...F x v System measures vertical Average and Peak Velocity of the weight lifted Using known mass system also calculates Average Power Peak Power and Peak Force in concentric phase of weight training To...

Page 5: ...mpartment screws using a Phillips screwdriver Battery compartment has a magnet for quick attachment to a rack or tripod Rechargeable batteries come pre charged ready for use Use NiMH AA size rechargea...

Page 6: ...ch the microcomputer magnet to the tripod s metal plate Rack Attach the microcomputer to the rack via the magnet on the back of your microcomputer unit Place the Unit under the barbell facing forward...

Page 7: ...k of the tripod to prevent its damage 2 3 Connecting microcomputer and sensor unit 1 Plug the male connector of your Data Cable into the connector at the bottom of the microcomputer The microcomputer...

Page 8: ...ensor unit to the bar dumbbell or top weight of the weight stack with the Velcro strap Position the cord so that during the exercise the trajectory of the cord will be as close to perpendicular to the...

Page 9: ...d eccentric average velocity if turned on Lower display shows repetition number and rest time if turned on Preset parameter avg peak power avg peak velocity partial avg power peak force in the first r...

Page 10: ...for full range of motion Peak velocity measured in meter per second m s the highest possible speed Peak Force measured in Newtons N maximum force for limited pre set range of motion motion from 0 to 1...

Page 11: ...display A LO limit for Partial Avg Power and Peak Force from 1 to 100 microcomputer indicates on upper display P AP Rest time ON OFF microcomputer indicates on upper display r t Eccentric average velo...

Page 12: ...ial Avg Power and Peak Force Rest time Eccentric velocity 6 4 1 Load It is possible to change a weight setting even if data are measured without resetting the microcomputer unit Use Up and Down button...

Page 13: ...display For instance take barbell from the rack or short movement while holding a barbell etc Setting range from 0 to 150 cm Use Up and Down buttons to change settings FILTER is a limit from 0 to a ce...

Page 14: ...r setting range from 0 to a certain predefined percent value of the range of motion Default setting is 50 Use Up and Down buttons to change settings Why should you measure Partial Average Power Someti...

Page 15: ...ovement and another at the end To filter out the undesirable peak at the end of the movement just shorten the range for the measurement of the Peak Force Ice hockey player Olympic weightlifter Body we...

Page 16: ...play is turned off to save battery power Any activity of the system turns on the displays To turn on the rest time press Up button in setting mode To turn off the rest time press Down button in settin...

Page 17: ...nector into the appropriate socket at the bottom of the microcomputer Plug the power supply adapter to the 110 230 V AC outlet Precautions Do not exceed the rated operating parameters The device may i...

Page 18: ...AA size rechargeable batteries 2000 2500 mAh If the batteries are located correctly in the battery compartment after the microcomputer is turned on the battery control LED light is flashing If the mic...

Page 19: ...possible to change the weight simply using Up and Down button without necessity to enter to the setup menu To scroll down the parameters in upper display press Mode button 9 3 Deleting Data Press Res...

Page 20: ...etition Upper display shows dEL To delete last repetition press Reset button again Exit from deleting process after the Reset or ON OFF button was pressed just press Up and Down button nnn in upper di...

Page 21: ...evices such as pacemakers and heart defibrillators can be adversely affected by strong magnetic fields 4 Credit Cards and Electronic Devices Credit cards computer disks and other magnetic storage devi...

Reviews: