TENDO V- 316 User Manual Download Page 19

9.2  Power, Velocity, Force measurement 

After each repetition, the repetition number begins to display on the lower display, actual value of 

average power, partial avg power and peak power, average velocity, peak velocity and peak force 

on the upper display and percent value of the best repetition on the middle display. 

It is possible to change the weight setting, even if data are measured, without resetting the 

microcomputer unit. Go to setup menu and change the weight using Up and Down buttons. 

To quit setup menu press Reset button.

The microcomputer will show you the exercise set data with different weight setting. 

To view particular repetition, press Down or Up button. Prior the repetition with changed 

weight, upper display will show "LoAd" and middle display will show new changed weight 

for the following repetition. 

If there are no measured data it is still possible to change the weight simply using Up and Down 

button without necessity to enter to the setup menu. 

To scroll down the parameters in upper display, press Mode button. 

9.3. Deleting Data

 

Press Reset. This calls up delete process for all the data. Upper display shows "rSt" and middle 

display shows "ALL". To delete all data, press Reset button, again. 

To leave deleting process after the Reset button was pressed, press Up and Down button. 

9.4 Deleting last repetition  

Press the ON/OFF button. This calls up delete process for last repetition data. The Upper display 

shows "dEL." Lower Display shows “Rep”. To delete last repetition, press ON/OFF again. 

To leave deleting process after the ON/OFF button was pressed once, press Up and Down button. 

9.5 Battery Saver 

 

The microcomputer has a built-in battery saver to prolong the battery life. After 2 minutes of 

microcomputer rest period, the battery saver is turned on (6 LED Mode lights flashing clockwise) 

and the microcomputer switches off the displays. The battery saver is turned off automatically by 

www.tendosport.com

19

Summary of Contents for V- 316

Page 1: ...TENDO Unit YOUR INTELLIGENT WEIGHT TRAINING Hardware User Manual www tendosport com 1...

Page 2: ...tup mode 12 6 4 What can be set up in setting mode 12 6 4 1 Load 12 6 4 2 Audio signal upper lower limits 12 6 4 3 Filter 13 6 4 4 limit for partial average power and peak force 14 6 4 5 Rest time mea...

Page 3: ...the system and give you an idea how to begin What comes as a part of the unit Microcomputer Sensor Unit Data Cable Tripod Rechargeable Batteries 4x of AA size type NiMH Built in Battery Charger AC DC...

Page 4: ...F x v System measures vertical Average and Peak Velocity of the weight lifted Using known mass system also calculates Average Power Peak Power and Peak Force in concentric phase of weight training To...

Page 5: ...mpartment screws using a Phillips screwdriver Battery compartment has a magnet for quick attachment to a rack or tripod Rechargeable batteries come pre charged ready for use Use NiMH AA size rechargea...

Page 6: ...ch the microcomputer magnet to the tripod s metal plate Rack Attach the microcomputer to the rack via the magnet on the back of your microcomputer unit Place the Unit under the barbell facing forward...

Page 7: ...k of the tripod to prevent its damage 2 3 Connecting microcomputer and sensor unit 1 Plug the male connector of your Data Cable into the connector at the bottom of the microcomputer The microcomputer...

Page 8: ...ensor unit to the bar dumbbell or top weight of the weight stack with the Velcro strap Position the cord so that during the exercise the trajectory of the cord will be as close to perpendicular to the...

Page 9: ...d eccentric average velocity if turned on Lower display shows repetition number and rest time if turned on Preset parameter avg peak power avg peak velocity partial avg power peak force in the first r...

Page 10: ...for full range of motion Peak velocity measured in meter per second m s the highest possible speed Peak Force measured in Newtons N maximum force for limited pre set range of motion motion from 0 to 1...

Page 11: ...display A LO limit for Partial Avg Power and Peak Force from 1 to 100 microcomputer indicates on upper display P AP Rest time ON OFF microcomputer indicates on upper display r t Eccentric average velo...

Page 12: ...ial Avg Power and Peak Force Rest time Eccentric velocity 6 4 1 Load It is possible to change a weight setting even if data are measured without resetting the microcomputer unit Use Up and Down button...

Page 13: ...display For instance take barbell from the rack or short movement while holding a barbell etc Setting range from 0 to 150 cm Use Up and Down buttons to change settings FILTER is a limit from 0 to a ce...

Page 14: ...r setting range from 0 to a certain predefined percent value of the range of motion Default setting is 50 Use Up and Down buttons to change settings Why should you measure Partial Average Power Someti...

Page 15: ...ovement and another at the end To filter out the undesirable peak at the end of the movement just shorten the range for the measurement of the Peak Force Ice hockey player Olympic weightlifter Body we...

Page 16: ...play is turned off to save battery power Any activity of the system turns on the displays To turn on the rest time press Up button in setting mode To turn off the rest time press Down button in settin...

Page 17: ...nector into the appropriate socket at the bottom of the microcomputer Plug the power supply adapter to the 110 230 V AC outlet Precautions Do not exceed the rated operating parameters The device may i...

Page 18: ...AA size rechargeable batteries 2000 2500 mAh If the batteries are located correctly in the battery compartment after the microcomputer is turned on the battery control LED light is flashing If the mic...

Page 19: ...possible to change the weight simply using Up and Down button without necessity to enter to the setup menu To scroll down the parameters in upper display press Mode button 9 3 Deleting Data Press Res...

Page 20: ...etition Upper display shows dEL To delete last repetition press Reset button again Exit from deleting process after the Reset or ON OFF button was pressed just press Up and Down button nnn in upper di...

Page 21: ...evices such as pacemakers and heart defibrillators can be adversely affected by strong magnetic fields 4 Credit Cards and Electronic Devices Credit cards computer disks and other magnetic storage devi...

Reviews: