OPERATING THE MACHINE

Powering On

Make sure the unit is plugged in.  Turn on the Main Power Switch that is located next to the power cord 
on the rear of the machine.  The red Power Indicator light on the Remote Control Panel will illuminate.  
If the Power Indicator light does NOT illuminate, press and release the Standby Button on the Remote 
Control Panel

Heating

When switched on, the red Heat Indicator light will illuminate and the machine will begin to heat up to 
its optimal temperature.  The initial heating cycle will take 7-10 minutes.  When the green Ready Indica-
tor light comes on, the machine is ready to make smoke. 

Control Options

There are several methods of controlling the Nightfall, including: Manual Control via the Remote  
Control Panel and Multi-Link control that allows multiple machines to be controlled from a single  
Remote Control Panel. 
Manual Control via the Detachable Remote Control Panel that is included with each machine.  An oper-
ator can control the unit at the machine, or from a distance using the included 3-pin cable.  The Remote 
Control Panel can be used to set smoke output volume, power the machine on and off using Standby 
mode, and set a repeating, timed cycle of on/off operation. 
Multi-Link allows up to 4 machines to be linked together via 3pin XLR cables (not included) and con-
trolled by a single Remote Control Panel. 

Using the Remote Control Panel

The Remote Control Panel can be operated directly on the machine or detached from the unit and used 
at a distance.  To detach the Remote Control Panel from the unit, loosen the thumb screws and lift the 
panel from its recessed mount.   A 15 foot (4.5m) cable is provided to allow the machine to be operated 
at a distance.  If needed, a longer 3-pin XLR cable can be used or joined to the existing cable.  Do not 
exceed a maximum distance of 165 feet (50 m) from remote to machine. 

When the green Ready Indicator light is illuminated, the Nightfall is ready to make smoke.   Press and 
release the Fog Button to begin producing smoke.  The red Power Indicator light will flash to indicate 
the machine is operating. To stop making smoke, press and release the Fog Button again. Adjust the Fog 
Level knob to increase or decrease the amount of smoke produced.  

The Standby Button allows the machine to be “turned off” from the remote without using the Main Pow-
er Switch.   In Standby mode, the machine will not reheat or make smoke, the pump remains unpowered 
and all indicator lights will switch off.  To engage Standby mode, press and release the Standby Button.  
The red Power Indicator light will turn off.   To disengage Standby mode, press and release the Standby 
Button again and the red Power Indicator light will turn back on.   Once Standby mode is disengaged, the 
machine will immediately start heating in preparation to make smoke.  Note:  If no remote is connected 
and no DMX signal is detected, the machine will not heat.

Using Timers
The timer controls allow you to set the machine to produce smoke in timed intervals without an  
operator.   To engage the timers, press and release the Timer Button.   The green Timer Indicator light will 
illuminate and the machine will begin to produce smoke at the level set by the Fog Level Knob, and the 
red Power Indicator light will flash to indicate the machine is operating. 

Summary of Contents for Shadow Nightfall

Page 1: ...N i g h t f a l l...

Page 2: ...the Detachable Remote Control Panel 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 8 9 Using Multi Link 9 Changing Fluid 9 Running Dry 10 Priming the System 10 Powering Down 10 Ducting...

Page 3: ...Nightfall other than genuine Rosco Smoke Simulation Fluids as they have not been tested for optimal performance and safety considerations Doing so may damage the machine and will void the warranty Not...

Page 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Page 5: ...eave the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine...

Page 6: ...et that allows for multiple machines to be daisy chained together and controlled from a single Remote Control Panel Main Power Switch Turns unit on or off by con trolling the flow of power to the unit...

Page 7: ...s engaged Fog Level Knob Rotate to set the desired amount of smoke output Higher numbers indicate more smoke Output is controlled by pump speed increasing and sending more smoke fluid into the heat ex...

Page 8: ...Slide the bottle cap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Shadow machines are primed at the factory with a small amount of fluid No additional...

Page 9: ...nel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cab...

Page 10: ...time that the machine waits before starting to produce smoke again The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table bel...

Page 11: ...is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long term storage DUCTING SMOK...

Page 12: ...te Fog Level Knob clockwise Rotate the Fog Level Knob clockwise Ensure filter is submerged See the Priming the System section of the manual Contact nearest Service Center for repair Machine produces s...

Page 13: ...sure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air...

Page 14: ...e continuous Warm up time 7 10 minutes Control and programming Control options timer remote Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections Remote Multi...

Page 15: ...14 Dimensions Dimensions are shown in inches and millimeters...

Page 16: ...damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or...

Page 17: ......

Page 18: ...NOTES...

Page 19: ...NOTES...

Page 20: ...Tempest Technology Corporation 4708 N Blythe Avenue Fresno CA 93722 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com...

Reviews: