background image

- 13 -

Storage & Shipment

Before storing the machine for an extended period of time, ensure the following:
•  Fluid bottle has been removed and securely capped
•  Proper cleaning of exterior as described above
•  Proper purging of the heat exchanger as described above
•  Machine is properly boxed or covered to avoid dust build up on internal components
•  If shipping, use original packaging or comparable protection to avoid damaging the machine in transit

SPECIFICATIONS

Physical
Length   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.59” (573.8 mm)
Width   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.94” (278 mm)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.82” (249.5 mm)
Dry weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24.25 lbs (11 kg)
Performance
Operating time   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .continuous
Warm up time   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 minutes
Control and programming
Control options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . timer remote
Fluid system
Capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120v - 4 liters / 240v - 5 litres
Fluid consumption    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.6  liters / hour
Connections
Remote / Multi-Link  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 pin XLR
AC power    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed power cable
Electrical
AC voltage   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120V / 230V, 50/60Hz
Main fuse (120V US version)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10AT
Main fuse (230V EU version)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5AT
Thermal
Maximum ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°C (104°F)
Exterior surface temperature, steady state, at 20°C ambient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°C (104°F)
Approvals
European EMC: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN61000-6-3,EN61000-3-2,EN61000-3-3,EN50366
European safety:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60 335-1
Immunity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN61000-6-1, EN61000-4-2,EN61000-4-3
ETL approvals (cETLus) pending  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL60335-1, CSA-E60335-1

Information in this document is subject to change without notice and does not represent a commitment on 
the part of Tempest .

Summary of Contents for Shadow Nightfall

Page 1: ...N i g h t f a l l...

Page 2: ...the Detachable Remote Control Panel 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 8 9 Using Multi Link 9 Changing Fluid 9 Running Dry 10 Priming the System 10 Powering Down 10 Ducting...

Page 3: ...Nightfall other than genuine Rosco Smoke Simulation Fluids as they have not been tested for optimal performance and safety considerations Doing so may damage the machine and will void the warranty Not...

Page 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Page 5: ...eave the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine...

Page 6: ...et that allows for multiple machines to be daisy chained together and controlled from a single Remote Control Panel Main Power Switch Turns unit on or off by con trolling the flow of power to the unit...

Page 7: ...s engaged Fog Level Knob Rotate to set the desired amount of smoke output Higher numbers indicate more smoke Output is controlled by pump speed increasing and sending more smoke fluid into the heat ex...

Page 8: ...Slide the bottle cap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Shadow machines are primed at the factory with a small amount of fluid No additional...

Page 9: ...nel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cab...

Page 10: ...time that the machine waits before starting to produce smoke again The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table bel...

Page 11: ...is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long term storage DUCTING SMOK...

Page 12: ...te Fog Level Knob clockwise Rotate the Fog Level Knob clockwise Ensure filter is submerged See the Priming the System section of the manual Contact nearest Service Center for repair Machine produces s...

Page 13: ...sure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air...

Page 14: ...e continuous Warm up time 7 10 minutes Control and programming Control options timer remote Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections Remote Multi...

Page 15: ...14 Dimensions Dimensions are shown in inches and millimeters...

Page 16: ...damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or...

Page 17: ......

Page 18: ...NOTES...

Page 19: ...NOTES...

Page 20: ...Tempest Technology Corporation 4708 N Blythe Avenue Fresno CA 93722 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com...

Reviews: