UNPACKING

Your Shadow Nightfall requires no assembly. Note: 230 volt machines are shipped with bare leads at the 
end of the power cord.
 A proper electrical connector must be attached based on the local power require-
ments. 
 Carefully remove the machine from the box.  Ensure that no tape or packing materials are stuck 
to the machine.  Stray packing materials that remain attached to high temperature areas of the ma-
chine could melt or burn during operation.   In particular, ensure that the area around the nozzle is free 
of any materials or debris.

CONTROLS

Multi-Link Socket
3-Pin XLR socket that allows 
for multiple machines to be 
daisy chained together and 
controlled from a single Remote 
Control Panel.  

Main Power Switch
Turns unit on or off by con-
trolling the flow of power 
to the unit.

Air-Input / Purge Connection
This is a push-to-connect inlet that accepts ¼”OD 

tubing and allows compressed air to blow through 

the heat exchanger for cleaning 

and maintenance. 

Heat Indicator 
A red indicator light that illuminates 
when machine is heating in order to 
achieve optimal temperature for  
producing smoke. 

Fluid Bottle

Ready Indicator
A green indicator light that illuminates when the 
minimum temperature for producing smoke has 
been achieved.  Note: All indicator lights will switch 
off if Standby mode is engaged.

Removable Remote

Remote Thumb Screws
Loosen to remove

Power Cable

Summary of Contents for Shadow Nightfall

Page 1: ...N i g h t f a l l...

Page 2: ...the Detachable Remote Control Panel 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 8 9 Using Multi Link 9 Changing Fluid 9 Running Dry 10 Priming the System 10 Powering Down 10 Ducting...

Page 3: ...Nightfall other than genuine Rosco Smoke Simulation Fluids as they have not been tested for optimal performance and safety considerations Doing so may damage the machine and will void the warranty Not...

Page 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Page 5: ...eave the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine...

Page 6: ...et that allows for multiple machines to be daisy chained together and controlled from a single Remote Control Panel Main Power Switch Turns unit on or off by con trolling the flow of power to the unit...

Page 7: ...s engaged Fog Level Knob Rotate to set the desired amount of smoke output Higher numbers indicate more smoke Output is controlled by pump speed increasing and sending more smoke fluid into the heat ex...

Page 8: ...Slide the bottle cap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Shadow machines are primed at the factory with a small amount of fluid No additional...

Page 9: ...nel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cab...

Page 10: ...time that the machine waits before starting to produce smoke again The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table bel...

Page 11: ...is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long term storage DUCTING SMOK...

Page 12: ...te Fog Level Knob clockwise Rotate the Fog Level Knob clockwise Ensure filter is submerged See the Priming the System section of the manual Contact nearest Service Center for repair Machine produces s...

Page 13: ...sure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air...

Page 14: ...e continuous Warm up time 7 10 minutes Control and programming Control options timer remote Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections Remote Multi...

Page 15: ...14 Dimensions Dimensions are shown in inches and millimeters...

Page 16: ...damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or...

Page 17: ......

Page 18: ...NOTES...

Page 19: ...NOTES...

Page 20: ...Tempest Technology Corporation 4708 N Blythe Avenue Fresno CA 93722 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com...

Reviews: