Cyclone User Manual
37
Single Feed Power Termination
•
Connect Earth/Ground wire to Ground Terminal
•
Connect Live and Neutral to the terminals marked L
and N ENCLOSURE
•
IMPORTANT: Use only copper wire, rated to comply
with local electrical codes. Terminal Screw Torque
Setting 0.5Nm/4.5in lb.
SEE DIAGRAMS ON FOLLOWING PAGES
Split Feed Power Termination
•
STOP! Did you cut the power links? See above.
•
Connect Earth/Ground wire to Ground Terminal
•
Connect Enclosure feed to the terminals marked L and N
ENCLOSURE
•
Connect Projector feed to the terminals marked L and N
PROJECTOR
•
Open the Split Feed Wiring Kit
–
it contains two short cables to
link the PROJECTOR supply terminals to the DEC SPLIT terminals:
•
Connect Split feed wires provided between L and N PROJECTOR
and motherboard L and N SPLIT terminals
•
IMPORTANT: Use only copper wire, rated to comply with local
electrical codes. Terminal Screw Torque Setting 0.5Nm/4.5in lb.
SEE DIAGRAMS ON FOLLOWING PAGES
Ferrules
–
connect to DEC
Terminals
Spades
–
connect to
supply terminal block