ALARM & WARNING LIST AND TROUBLESHOOTTING
-
EMERGENCY STOP IS PRESSED !
Please unpress the Emergency Stop on control panel
-
PHASE CONTROL ! 380V
Please check the phase ranking is not correct. On this case
hydraulic pump can not work. This means there is no tention on
blade. If no tention on blade machine can not start.
-
SECURITY MODULE IS WAITING FOR RESTART !
Machine need to be restarted. Switch off the main switch then
wait 10 second to open it again.
-
HYDRAULIC MOTOR THERMIC ERROR !
Hydraulic pump motor has too high temperature on, please
check the wiring and be sure that the motor wires connected
and tithed well.
-
HYDRAULIC LOW PRESSURE ! PRESSURE SW
Look at the I-O tracking if hydraulic pump motor is working.If
not work please contact the producer company to replace the
motor. In case motor work well please check the pump which is
connected to the motor. If pump has mallfunction contact the
producer company to replace the pump.
-
DOOR SWITCH 1 OPENED
Click on door switch indicator button to see which door is
opened. Close the door. In case door is closed please check the
switch on the door is it in function or no. If yes then contact the
producer company to solve your problem online. If no then
replace the switch with the new one.