background image

19

78570

TEMCO FIREPLACE PRODUCTS GAS LOGS & FIREPLACES

INSTALLATION AND STARTUP CHECKLIST

Installer’s Copy

NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer.
A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior
written approval of warranty repair or replacement.

All Vent-Free Gas Fireplaces and Logs

Read and understand installation instructions before attempting installation.

Assure that the model to be installed is of the CORRECT FUEL TYPE. Check markings on the shipping container (Model #’s
ending in “N” are natural gas products; models #’s ending in “P” are LP gas products.), tags on the burner assembly.

NOTES: REGULATORS ARE NOT FIELD-ADJUSTABLE. ANY ATTEMPT TO ADJUST VOIDS THIS WARRANTY.

In order to ensure adequate combustion air, make sure that the model being installed has the appropriate heating
capacity for the unconfined space available. 
Allow a minimum of 50 cubic feet of unconfined space per 1000 BTU’s for all
gas appliances.

Assure that gas line size is adequate for the model’s input rating (BTU’s per hour), the  length of run from the meter or
second stage regulator to the farthest gas appliance, and other gas appliances on the system. A drip leg or sediment trap is
required. LP models require a minimum tank size of 120 gallons water capacity and two stage regulation.

Assure that installation meets local codes and ordinances.

Assure that there are no fans or blowers in the fireplace area.

Check for leaks before lighting.

Using a manometer, verify proper gas pressure at the manifold with unit at maximum setting and other appliances
operating.

inlet pressure: _______ (ins. wc)

manifold pressure: ________ (ins. wc)

Verify proper ignition of ODS and front and rear burners, as well as proper appearance of flames.

Verify that ceramic fiber and refractory components are properly positioned and secure. (Rear burner must not
contact logs.)

Verify adequate clearance to mantels and other combustibles.

Demonstrate correct operation of the product to the consumer. NOTE: LP models must not be operated if fuel tank is less
than 1/4 full.

Observe the consumer operating the product properly.

Explain and demonstrate proper periodic maintenance.

Explain that operation with logs positioned other than as described in the manual voids the warranty and will cause poor
combustion and sooting.

Verify the consumer’s understanding that warranty service work that is not pre-approved by the manufacturer’s Technical
Service Department (other than routine maintenance) may not  qualify for reimbursement.

Answer any questions the consumer may have about TEMCO Fireplace Products vent-free products.

Vent-Free Gas Logs Only

Verify that the fireplace in which the logs are to be installed is either a solid-fuel burning fireplace (either factory-built or
masonry) with a working flue system connected to it or an  approved vent-free firebox.

Verify that the fireplace has been thoroughly cleaned by a professional chimney sweep. If solvents have been used to clean
the hearth,  they must be allowed to evaporate before proceeding with installation.

Check firebox dimensions for adequate height, width, and depth.

Verify that the grate assembly is attached to the firebox floor.

Verify that any ash dump or outside air inlets are permanently sealed to avoid drafts within the firebox.

Verify that no additional logs, ornaments or non-approved blower devices have been added.

Repair any broken or damaged logs prior to operation.

Check mantel clearances and verify installation of canopy if necessary.

Glass doors must be removed or opened completely during operation of logs.

Please sign below that checklist has been completed and understood. DATE INSTALLED ____/____/____

Installer

Phone

Consumer

Phone

Summary of Contents for VFL34MN

Page 1: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Section Provisions For Adequate Combustion and Ventilation Air Page 4 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do n...

Page 2: ...ighting 13 Flame Check 13 Managing Heat Output 14 Maintenance Cleaning 14 Troubleshooting 15 Servicing 15 Repair Parts 16 Warranty Information 17 Installation and Startup Checklist 18 Warranty Registration 20 Table of Contents Minimum Dimensions for Existing Solid Fuel Burning Fireplaces This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohib...

Page 3: ...DO NOT use this heater in recreational vehicles bedrooms or bathrooms If this is the ONLY gas appliance we recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound cylinder is not recommended Other household gas appliances may require the tank size to be larger Do not operate the vent free heater if the fuel level in the propane tank is below 1 4 full DO NOT use this heater if a...

Page 4: ...e Example Space size 25 length x 25 width x 8 ceiling height 5 000 cu ft volume of space If additional ventilation from adjoining room s is supplied with grills or doorless openings add the volume of these rooms to compute the total volume of the applicable space 2 Divide the space volume by 50 cubic feet to determine the maximum BTU Hr the space can support ________ volume of space 50 cu ft Maxim...

Page 5: ...onal Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent L W D Flue Damper Closed for Unvented Operation and Maximum Heat Output Flue Damper Locke...

Page 6: ... do so could cause gas leaks Holes are provided in the sheet metal chassis Fig 3 and should be used for securing the log set After locating the chassis correctly in the fireplace mark the hole positions on the fireplace floor Drill two 1 8 diameter holes approximately 1 2 deep Use the two screws to secure the chassis to the fireplace floor Fig 3 Clearances NOTE The following instructions regarding...

Page 7: ...ol valve gas line inlet The inlet to these units is 1 2 NPT If installation is for L P gas have L P installer use two stage regulation and make all connections from storage tank to heater Refer to the National Fuel Gas Code for the proper supply tank size with the Btu s Hr requirements If this is the ONLY gas appliance we recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound ...

Page 8: ... for specific requirements Piped Gas Supply Drop Manual Shut Off Valve Horizontal Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N P T Plugged Hole for Test Gauge Gas Valve Drop Manual Shut Off Valve Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N P T Plugged Hole for Test Gauge Gas Valve Tubing Gas Supply Riser Manual Shut Off Valve Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N...

Page 9: ... 7 0 w c 11 0 w c Min 5 0 w c 10 8 w c Regulator Pressure 3 5 w c 10 0 w c Minimum inlet supply pressure for the purpose of input adjustment Gas Pressure Check The gas inlet pressure specified in Table 1 is the pressure where the field installed gas line connects to the gas control This is measured at the inlet test port on the gas valve in the appliance Ensure that pressure is as shown in Table 1...

Page 10: ...c ash on burner pilot or logs 6 Platinum embers are to be placed only on top of the front burner port area Equally space emblers one layer thick Do not pile ember material over one layer thick as this does not enhance the ember appearance or improve the log set performance Fig 8 7 Flames must not impinge touch on logs WARNING Do not use more embers than those supplied with your unit Do not use emb...

Page 11: ... connecting a wall switch thermostat or remote control use only the top and bottom control valve terminals for attachment of the wire leads do not use center terminal of terminal block Figs 9 and 10 Remote Control Information The remote receiver does not need to be secured to the VFL34R N P base but can be placed along side of the log base assembly larger fireboxes only in a wall mounted switch bo...

Page 12: ...en smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 4 Refer to Figure 13 Locate the pilot It is positioned on the burner behind the front log and below the right twig times This will cause a spark at the pilot which will ignite the pilot gas 7 Hold the control knob for 20 seconds to prevent the flame fa...

Page 13: ...pliance is operating WARNING The glowing ember base and all the logs are manufactured from bonded ceramic fiber This is a commonly used material in industry worldwide In the event of the logs and base being removed care should be taken not to damage the bonded material Intentional misuse of or deliberately fragmenting the material could lead to inhaling fibers and be injurious to health Insure the...

Page 14: ...e required under normal use Dusting the front grate or the control knob panel may be required occasionally Do not use any cleaning fluids to clean the logs or any other part of the appliance If the flames show any unusual shapes or behavior or if the burner s fail to ignite properly then the burner holes may require cleaning If this occurs contact your nearest dealer to get the appliance serviced ...

Page 15: ...lace assembly Ignitor cable pinched or broken Free ignitor cable if damaged replace it Ignitor cable not connected to ignitor Connect cable to ignitor 2 Pilot will not stay lit Partially clogged ODS pilot orifice Contact qualified service person or your gas company Corrosion of thermocouple contact Clean thermocouple contact Bad gas valve Replace gas valve Control knob not pressed in long After pi...

Page 16: ...78439 1 Air Scoop 78445 78445 1 Valve Natural 55463 1 Valve LP Propane 55462 1 Burner Natural 78474 1 Burner LP Propane 78473 1 Pilot Natural OP 78167 1 Pilot LP Propane OP 78169 1 Manifold Tube Split Nut 78456 78456 1 Orifice 31 Natural 78458 1 Orifice 50 LP Propane 78451 1 Tube Flexible Gas Inlet 71598 71598 1 Tube Pilot 3 16 78583 78583 1 Ignitor w Nut Piezo 65180 65180 1 Wire Assembly Rocker S...

Page 17: ...allation instructions and in compliance with local codes and ordinances The logs must be placed strictly in accor dance with the arrangement described in the installation instructions The Product must be operated and maintained according to the instructions furnished Alteration of the Product in any way is prohibited and voids any and all war ranties Removal of the data plate alters the Products a...

Page 18: ...rners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer NOTE LP models must not be operated if fuel tank is less than 1 4 full Observe the consumer operating the product...

Page 19: ...burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer NOTE LP models must not be operated if fuel tank is less than 1 4 full Observe the consumer operating the produ...

Page 20: ...er your warranty please provide the information indicated on this form and mail it to TEMCO Fireplace Products Attn Warranty Registration 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Model ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installation and startup chec...

Reviews: