Serviceable Components
General
The following NET-PATHm components can be serviced either at the factory or in the
field.
UPS Battery
The NET-PATHm contains a 12-volt, rechargeable UPS battery. The life expectancy is
one to three years, depending on variables such as temperature and recharge cycles.
The NET-PATHm fixed event messages signal when the battery is unable to hold a
charge, or is constantly charging. Battery replacement kits are available from
Teltronics.
Use care when working with your battery. Do not to touch the battery with conducting
materials, such as rings, bracelets, keys, and tools. Do not open or mutilate the
battery. Do not dispose of the battery in fire.
Field
Description
UPS Battery
Replacement kits are available from Teltronics. You
can replace this unit in the field. See “UPS Battery
Replacement Procedure” on page 5-2.
Coin Cell Battery
The coin cell battery has a service life is four to five
years. This unit can be replaced in the field. See “Coin
Cell Battery” on page 5-2.
Warning
There is a danger of explosion if you replace the
battery incorrectly. Replace only with the same or
equivalent battery type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s
instructions.