background image

Page 4-1

4

Indicators and Diagnostics

Front Panel 
Indicators 

The NET-PATHm front panel contains four Light Emitting Diode (LED) indicators. 
The LEDs indicate the power status, battery charge status, application or database 
status, and alarm conditions.

Figure 4-1 NET-PATHm Front Panel Indicators

Indicators

The four LED indicators on the NET-PATHm front panel indicate the following 

conditions. 

LED

Description

Power

ON indicates the NET-PATHm is using commercial power.

Off indicates the NET-PATHm is operating on battery power. 

Battery

ON indicates the battery is fully charged.

FLASHING, indicates the battery is charging.

OFF, indicates the battery is disconnected.

Status

FLASHING indicates the NET-PATHm is loading the application 
and database.

ON indicates the NET-PATHm has a valid database loaded.

OFF indicates the NET-PATHm does not have a valid application 
or database loaded. 

Alarm

ON indicates that an alarm condition exists.

OFF indicates normal operation

Summary of Contents for SEB NET-PATHm

Page 1: ...SEB NET PATHm Installation and Operation Guide...

Page 2: ......

Page 3: ...SEB NET PATHm Installation and Operation Guide...

Page 4: ...5 2009 Teltronics Inc All rights reserved The material in this document has been carefully reviewed however Teltronics Inc does not guarantee it to be free of all errors or omissions and reserves the...

Page 5: ...Added NET PATHm DC Power section Chapt 5 04 06 Revision F Updates to the Power Requirements section Chapt 1 09 05 Revision E Updates to the Script command line interface command with the ScriptParm o...

Page 6: ......

Page 7: ...ing Tables 2 5 Temperature Sensor 2 5 Power 2 5 Reset Button 2 6 Battery 2 6 Power Up and Verification 2 6 Failover 2 7 Return the Database to a Default State 2 7 Internal Battery Test 2 7 Functional...

Page 8: ...t Button 4 2 UPS Off Button 4 2 Modems 4 2 Troubleshooting 4 6 Troubleshooting Incoming Calls 4 6 Troubleshooting Outgoing Calls 4 7 Serviceable Components General 5 1 UPS Battery 5 1 UPS Battery Repl...

Page 9: ...ents for Consumer Products The Federal Communications Commission FCC has established Rules which permit this device to be directly connected to the telephone network This equipment complies with FCC P...

Page 10: ...Company or to one of our authorized agents Service can be facilitated through our office at Teltronics Incorporated 2150 Whitfield Industrial Way Sarasota FL 34243 4046 TEL 941 753 5000 Canadian Noti...

Page 11: ...sur le brouillage radio lectrique dict par le minist re des Communications du Canada Professional installation only no user serviceable parts inside except as indicated in this installation guide Impo...

Page 12: ...un orage lectrique Ceci peut pr senter un risque de choc lectrique caus par la foudre Ne pas utiliser l appareil t l phonique pour signaler une fuite de gaz s il est situ pr s de la fuite Utiliser seu...

Page 13: ...methods of measurement of radio interference characteris tics of information technology equipment EN 50024 1 Information technology equipment Immunity characteristics Limits and methods of measurement...

Page 14: ...TBR 21 However the SEBea does not meet the more unusual requirements for maximum voltage in the loop state as specified in specification EG 201 121 V1 1 1 advisory note NO 02 for Norway and Advisory...

Page 15: ...Return for Repair Customers can return to Teltronics at customer s risk and expense any Teltronics product that fails in normal service during the warranty period The failed product will be repaired...

Page 16: ...ed parts and will carry a new parts warranty of ninety days from the shipping date Return Authorization A return authorization number must accompany all equipment returned to Teltronics for repair or...

Page 17: ...l This manual only covers the database to that point necessary for the installer to ensure the NET PATHm functions properly This manual consists of the following sections Physical Description And Spec...

Page 18: ...Preface xii Notes...

Page 19: ...n variables include SNMP Segment Management software and AC or DC input power Determining the NET PATHm Model The serial number and model information is on a label attached to the bottom of the unit F...

Page 20: ...d host port Description The NET PATHm is housed in an aluminum case Connections for commercial power the host systems external sensors terminal and the telephone line are on the back of the unit See C...

Page 21: ...r data Non volatile 16 MB embedded None SDRAM Operating Memory Available memory for operating system and applications Volatile downloadable 64 MB DIMM single socket None RTC Real Time Clock Yes N A An...

Page 22: ...the NET PATHm labeled Host 1 and Host 2 are configured as Data Terminal Equipment DTE using RJ45 male connectors Transmission rates can vary from 110 BPS to up to 115 KBPS Telephone Line Interface The...

Page 23: ...memory technology Flash memory does not require a power source to retain stored data MTBF Mean Time Between Failure MTBF is in excess of 60 000 hours per Bell IP 10425 Battery Backup When fully charg...

Page 24: ...Description and Specifications Page 1 6 Notes...

Page 25: ...emperature to rise Excessively dry areas can cause static charge buildup resulting in operating faults and the destruction of semiconductor devices Unpacking Before opening the shipping container insp...

Page 26: ...must loopback the DSR and RTS signals on the end of the cable connected to the host and ensure the signal passes through to the cable to the remote agent Doing so allows the remote agent to detect con...

Page 27: ...ATHm database NET PATHm contact sensors support two types of input sensing The first type of input sensing is based on RS232C and supports wet input The second type is also based on RS232C and it supp...

Page 28: ...nactive open These values assume worst case tolerances Logical states include active and inactive and though database options may be considered the alarm or no alarm state depending on the application...

Page 29: ...r is positioned near the UPS battery charging circuit and is used to detect excessive charging temperatures that may occur during abnormal charging conditions The battery charger is turned off until t...

Page 30: ...l Figure 2 5 UPS Battery Self Discharge Characteristics Power Up and Verification Apply commercial power to the unit and observe the front panel indicators After several seconds the Power indicator sh...

Page 31: ...3 After about fifty seconds this may vary with your unit the Alarm LCD flashes red once When this occurs press the Reset button again 4 The database will return to its default state Internal Battery...

Page 32: ...rent to an attached host device using the NET PATHm Command Line Interface See Useful Command Line Interface Commands on page 3 5 If a serial connection does not function as expected verify the port c...

Page 33: ...NET PATHm and program it with an application and a database The application contains all operating software for the NET PATHm features A license key controls the enabled features The application softw...

Page 34: ...the NET PATHm use one of the following methods Use a third party terminal program to connect via null modem cable to a serial port on the NET PATHm Use a third party terminal program to connect to th...

Page 35: ...ion currently running on the NET PATHm 3 Type login then press the Enter key The User name prompt displays 4 Type your user name then press the Enter key The Password prompt displays 5 Type your passw...

Page 36: ...ch you wish to communicate 2 Select the NET PATHm by right clicking the icon From the pop up menu select Remote Agent Manager 3 When the RA Manager screen finishes loading select the telephone icon fr...

Page 37: ...erforms a battery load test Option START STOP BEEP BEEP Option Example BEEP ENABLED BEEP DISABLED Enables or disables the buzzer Option ENABLED DISABLED CD CD Directory Examples CD TEMP CD FLASH TEST...

Page 38: ...more than one modem configured Please specify the modem instance or name 1 Main Modem 2 Secondary Modem If you specify any device other than MODEM an error is returned When entering strings e g Modem...

Page 39: ...access port serial NIC modem Show displays the current Debug Options SET x y z changes the Debug Options and persist it to the PM SET options ALL All NONE None LOG Log to the DEBUG DAT ACT Action ACW...

Page 40: ...I CONTACT RELAY TEMPERATURE DIR DIR Path s Examples DIR DIR FLASH TEST s DIR s Gets the directory structure If you do not specify a path the current directory is used Path specified path for directory...

Page 41: ...vent pipeline Host displays only host related engine information Action displays only action related engine information Summary displays information in a summary format Noevent does not display any ev...

Page 42: ...R VOLTAGE MEMORY MODEM NIC SERIAL SYSTEM UI CONTACT RELAY TEMPERATURE BUZZER LED and RTC DeviceName name of the device that we are logging SearchString the search parameters used to control the data s...

Page 43: ...earch Expression Examples NDPOLL FLASH File Wrap100k t1 75 ABC Host 1 DTA005 22 Note Alternately you can just type NDPOLL to display a menu list of file types and host names from which to choose Note...

Page 44: ...e contents of the raw data buffer SerialPortName name of NET PATH serial ports 1 8 Direction IN or OUT RD RD Directory Example RD FLASH Users Jones Removes an existing directory Directory name of dire...

Page 45: ...erminal type or speed used RLOGINHOST RLOGINHOST HostName Example RLOGINHOST XYXHost Establish an RLOGIN session using the target host name HostName the name of the target host device RUN RUN ScriptNa...

Page 46: ...t was suspended QUEUE script name Takes an additional argument of script name Adds the specified script to the queue for the specified host FLUSH Flush all pending scripts from the queue for the speci...

Page 47: ...ctions TIME TIME HH MM SS Examples TIME TIME 14 02 00 Sets gets the current time If you do not specify time the current time is retrieved TYPE TYPE filename Examples TYPE MyFile Brings the specified f...

Page 48: ...hat host Once a session is established the system sends any characters received from the host to the connected user and also passes them to the application or script for processing Characters sent fro...

Page 49: ...conditions LED Description Power ON indicates the NET PATHm is using commercial power Off indicates the NET PATHm is operating on battery power Battery ON indicates the battery is fully charged FLASH...

Page 50: ...the modem s country code setting for Multi Tech modems with model number MT5634SMI To display the country code currently in use Type Status Modem on the command line The system returns the modem init...

Page 51: ...inland France Germany Greece Guatemala Iceland Ireland Italy Jamaica Luxemburg Macao Mexico Netherlands Netherlands Antilles Norway Pakistan Panama Peru Portugal Qatar United Arab Emirates Dubai Unite...

Page 52: ...DEM A modem enum value of 0239 indicates your NET PATHm has the Multi Tech modem 2 Change the country code Login to the NET PATHm command line and type STATUS MODEM The modem returns a status modem re...

Page 53: ...rg Netherlands Norway Portugal Russian Federation Slovakia Spain Sweden Switzerland Turkey United Kingdom Cyprus Liechtenstein Lithuania FD 33 Taiwan FE Note When programming a Multi Tech modem model...

Page 54: ...Hm is off hook trying to place a call Use the CLI Status command to check the modem status Defective telephone cable Replace cable NET PATHm answers off hook but no carrier is detected DCD is OFF Poss...

Page 55: ...end is not set for auto answer Restricted telephone line Contact your local telephone representative Call was received at the Polling and Analysis Center but did not have a carrier Possible Cause Non...

Page 56: ...Indicators and Diagnostics Page 4 8 Notes...

Page 57: ...ot to touch the battery with conducting materials such as rings bracelets keys and tools Do not open or mutilate the battery Do not dispose of the battery in fire Field Description UPS Battery Replace...

Page 58: ...PATHm 12 Reinstall the cover and replace the retaining screws 13 Attach the cables to NET PATHm 14 Apply power to the unit 15 The battery LED indicator should illuminate to indicate that the battery...

Page 59: ...ine Interface or by downloading a new database See Useful Command Line Interface Commands on page 3 5 NET PATHm DC Power If you purchased a NET PATHm with a DC power connection you must connect the po...

Page 60: ...Hm only Initial shipments 540 2000 0044 AC Power Supply 100 240VAC 18VDC 1A 100 240 VAC In Line Brick 2 5 mm AULT INC PW118RA1803F01 NET PATHm only Standard offering after initial shipments 540 2000 0...

Page 61: ...nity requirements i vii external power supplies 5 4 F failover 2 7 FCC i iii flash memory 3 1 front panel indicators 4 1 functional verification 2 7 G general operation 3 1 H hardware features connect...

Page 62: ...2 2 serial ports 1 4 S safe shutdown 5 2 safety instructions i v SDRAM 3 1 sensor inputs 1 4 temperature 2 5 serial number 1 1 serial port 3 2 service requirements i iv serviceable components 5 1 site...

Page 63: ......

Page 64: ...SEB NET PATHm Installation and Operation Guide Teltronics Inc 2150 Whitfield Industrial Way Sarasota FL 34243 941 753 5000 Part Number 610 0000 0447 Rev I...

Reviews: