Serviceable Components
Page 5-2
UPS Battery
Replacement
Procedure
The replacement battery assembly includes a metal bracket and cable assembly.
To replace the NET-PATHm UPS battery
1
Remove the commercial power connection from the rear of the NET-PATHm.
2
Press the UPS Off button to perform a Safe Shutdown.
3
Disconnect the cables from the back of the NET-PATHm. Be sure to mark your
cables so you can reconnect them quickly.
4
Remove the screws that secure the NET-PATHm rear panel.
5
Remove the battery retaining screws on the bottom of the NET-PATHm.
6
Carefully slide the main board from the case.
7
Disconnect the battery power connector from the main board.
8
Remove the screw that secures the battery to the main board.
9
Lift the battery off the main board .
10
Insert the new battery assembly and secure it with the retaining screws. Be sure
the new battery has the same physical and electrical orientation as the old battery.
11
Attach the new battery power connector to the main board making sure the red
wire is on the left when viewed from the front of the NET-PATHm. Be careful.
The connector is keyed, but it is possible to force it in backwards. This will
change the polarity of the battery and will damage the NET-PATHm.
12
Reinstall the cover and replace the retaining screws.
13
Attach the cables to NET-PATHm.
14
Apply power to the unit.
15
The battery LED indicator should illuminate to indicate that the battery is fully
charged, or flash slowly to indicate that the battery is charging. If the battery
LED indicator is off, the new battery may be defective, or its polarity may be
incorrectly oriented. Check the connector to ensure it is plugged in correctly. Red
connects to the positive terminal and black to the negative terminal of the battery.
Coin Cell
Battery
A 3-volt, 175 mAh lithium coin cell battery maintains the NET-PATHm Real Time
Clock (RTC) settings. The life of this battery is normally four to five years.
Teltronics recommends that you replace this battery whenever you replace the NET-
PATHm 12-volt UPS battery. Replace the battery with a Panasonic BR2325, or
equivalent.
To replace the coin cell battery
1
Remove the commercial power connector from the back of the NET-PATHm.
2
Press the UPS Off button to perform a Safe Shutdown.
3
Disconnect the cables from the back of the NET-PATHm. Be sure to mark you
cables so you can reconnect them quickly.
4
Remove the screws that hold the NET-PATHm rear panel.
5
Remove the battery retaining screw on the bottom of the unit and slide the main
board attachment out of the case.
6
Locate the coin cell battery. Note the polarity. You should see a positive (+)
symbol on top of the battery.
Summary of Contents for SEB NET-PATHm
Page 1: ...SEB NET PATHm Installation and Operation Guide...
Page 2: ......
Page 3: ...SEB NET PATHm Installation and Operation Guide...
Page 6: ......
Page 18: ...Preface xii Notes...
Page 24: ...Description and Specifications Page 1 6 Notes...
Page 56: ...Indicators and Diagnostics Page 4 8 Notes...
Page 63: ......