![Teltonika FM1120 User Manual Download Page 84](http://html1.mh-extra.com/html/teltonika/fm1120/fm1120_user-manual_1084739084.webp)
84
1 – Low priority
2 – High priority
3 – Panic priority
20x1
Generation type
0 – Event on exit
1 – Event on entrance
2 – Event on both
3 – Monitoring
4 – Hysteresis
5 – On change
20x2
Low level
See table 9.4 –
Allowed
Values
20x3
High Level
Table 9.4 LV-CAN200 IO parameters allowed values
LV-CAN200 IO Element
Minimum
value
Maximum
value
Speed
0
250
Accelerator pedal position
0
100
Total fuel used
0
99999999
Fuel level (liters)
0
100
Engine RPM
0
8200
Vehicle distance
0
2145000000
Fuel level (proc.)
0
100
Program number
0
999
9.6
CAN Program Number request by SMS
CAN program number can be obtained via SMS:
SMS Text:
“
lvcangetprog
”
Response:
“
CAN Program Nr: XXX
”
9.7
Get LV-CAN info by SMS
Full LV-CAN information via SMS:
SMS Text: “ lvcangetinfo”
Response:
“Prog: 139
SWRevison: 6
KernVer: 10
KernVar: 49
MdlID: 8884443332221110”
9.8
References
1.
Light Vehicles Can adapter LV-CAN200 Supported cars
2.
Cars mounting scheme