![Teltonika FM1120 User Manual Download Page 61](http://html1.mh-extra.com/html/teltonika/fm1120/fm1120_user-manual_1084739061.webp)
61
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
Empty
65535
-
GPRS content activation (ID=1240)
U16
8.4.7
Protocol (ID=1247)
Parameter defines GPRS data transport protocol. Module can use TCP or UDP transport
protocol to send data to server. For TCP protocol value is 0, for UDP protocol value is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
GPRS content activation (ID=1240)
U8
8.4.8
SMS Login (ID=1252)
User login is used to ensure module security. Used in every SMS that is sent to device.
Example: ba321
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
Empty
5 char
-
S8[5]
8.4.9
SMS Password (ID=1253)
User password is used to ensure module security. Used in every SMS that is sent to device.
Example: ab123
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
Empty
5 char
-
S8[5]
8.4.10
SMS data sending settings (ID=1250)
Parameter allows or does not allow sending AVL data using binary SMS. If SMS use is not
allowed value is 0 and 1 if SMS use is allowed.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
S8
8.4.11
SMS Data send week time schedule (ID=1273)
Parameter defines SMS data sending according to week time schedule. This parameter is
used to set data sending on selected week days and hours. Minimum time step is 10 minutes.
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
For more information
read 8.5.1.4 “Schedule parameter format”.
8.4.12
Authorized phone numbers (ID=1260-1270)
If at least one number is entered then only those number can send messages to device.
Number must be entered without “+” or “00”.
Example: 37060012346