![Teltonika FM1120 User Manual Download Page 37](http://html1.mh-extra.com/html/teltonika/fm1120/fm1120_user-manual_1084739037.webp)
37
DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (configured Ignition
Source=1). After iButton ID is read (any iButton is attached), DOUT2 turns OFF. After iButton
identification ignition can be turned OFF (configured Ignition Source =0) for no longer than 30
seconds, otherwise immobilizer must be repeated.
5.13.2
Trip settings
Trip window offers user to configure Trip feature. If Trip is enabled configuration of
parameters are enabled.
Start Speed – GPS speed has to be greater than the specified Start Speed in order to detect
Trip Start.
Ignition Off Timeout – timeout to wait if ignition was off, to detect Trip stop.
Continuous distance counting – Not or Continuous can be chosen. For this feature I/O
Odometer must be enabled.
If I/O Odometer is enabled and Continuous distance counting variable is set to Continuous,
Trip
distance
is going to be counted continuously (
from Trip start to Trip stop
). This value is
written to I/O Odometer value field. When Trip is over and next Trip begins, Odometer value is
reset to zero. When the next trip starts counting continuously starts from the beginning again.
If I/O Odometer is enabled and Continuous Distance Counting variable is set “Not”, then
the distance is going to be counted only between every record made. This value is written to I/O
Odometer value field and reset to zero every new record until Trip stops. If later all Odometer
values are summed up manually, the user gets the distance driven during the whole period of the
Trip.
Figure 32 Trip configuration