Activation Timeout (ID=1102)
Parameter represents AutoGeofencing activation timeout in seconds.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
60
Enable/Disable (ID=1101)
U16
8.6.11.3
Deactivate by (ID=1100)
Parameter defines Autogeofence deactivation source. Value 1 is dedicated for attached
iButton, value 0 – for Ignition.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
Enable/Disable (ID=1101)
iButton List (ID=1610-1659)
U8
8.6.11.4
AutoGeofence event Priority (ID=1103)
Parameter defines AutoGeofence event priority: 0 is low, 1 – high;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
Enable/Disable (ID=1101)
AutoGeofence event generating
(ID=1104)
U8
8.6.11.5
AutoGeofence event generating (ID=1104)
Generate event: 0 – no event, 1 – on entering zone; 2 – on exiting zone; 3 – on both;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
2
Enable/Disable (ID=1101)
AutoGeofence event Priority
(ID=1103)
U8
8.6.11.6
Radius (ID=1105)
Parameter represents radius of circle with center device coordinates after activating
AutoGeofence feature.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1000000
100
Enable/Disable (ID=1101)
Deactivate by (ID=1100)
U32
8.6.12
iButton List (ID=1610-1659)
Read 5.4.4.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
FFFFFFFF
FFFFFFFF
-
Digital Output No.2 usage
scenarios (ID=1601)
Deactivate by (ID=1100)
U64