![Teltonika FM1110 User Manual Download Page 65](http://html1.mh-extra.com/html/teltonika/fm1110/fm1110_user-manual_1084738065.webp)
65
scenarios (ID=1600)
8.6.4
Max allowed Speed (ID=1605)
It is max allowed speed which can be reached. If this value exceeded Over speeding event
will occur.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
260
-
Digital Output No.1 usage
scenarios (ID=1600)
U16
8.6.5
Digital Output No.2 usage scenarios (ID=1601)
Device can operate in its scenario according to selected value: No Scenario for Digital No.2
selected (value 0); Authorized Driving (value 1), Immobilizer (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
iButton List (ID=1610-1659)
U8
8.6.6
Trip (ID=1150)
This parameter enables ability to detect START and STOP of the trip.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
8.6.7
Start Speed (ID=1151)
This parameter represents speed, which is detected as minimum speed to indicate TRIP
START and generate event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Trip (ID=1150)
U8
8.6.8
Ignition Off Timeout (ID=1152)
This parameter represents timeout to wait if ignition is off in order to detect TRIP STOP and
generate event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
Trip (ID=1150)
U16
8.6.9
Trip Continuous distance counting (ID=1153)
For this feature I/O#11 ODOMETER must be enabled. If I/O ODOMETER is enabled, and
Continuous distance counting variable is set to Continuous (value 1), TRIP distance is going to be
counted continuously (from TRIP start to TRIP stop) and shown as I/O ODOMETER value.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
Trip (ID=1150)
U8
Downloaded from
www.Manualslib.com
manuals search engine