![Teltonika FM1110 User Manual Download Page 53](http://html1.mh-extra.com/html/teltonika/fm1110/fm1110_user-manual_1084738053.webp)
53
F
8
Parameter List
8.1
Parameters value types
S8
– Signed Char
S8[
n
] – String of
n
Char
U8
– Unsigned Char
U16 – Unsigned Short
S32
– Signed Integer
U32 – Unsigned Integer
U64 – Unsigned Long Long Integer
8.2
System parameters
8.2.1
Sleep Mode (ID=1000)
Device has two sleep modes: sleep and deep sleep mode. While sleep is disabled (value 0)
module will never enter sleep mode, in sleep mode (value 1) module reduces level of power
usage by turning GPS module to sleep, in deep sleep mode (value 2) module turns GPS module to
sleep and switch GSM module off (note, that FM1110 do not receive SMS while in deep sleep).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
8.2.2
Sleep timeout (ID=200)
Sleep timeout is time after which FM1110 goes to sleep or deep sleep if other
requirements are met. It is measured in minutes.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
3000
-
U8