ISDN Line Simulator User’s Manual
40-400-00012, Rev. E
13
General Operation
Provisioning of features using the ILS-2000 configuration software allow the
user to select from several stored configurations, as well as allow the user to
store other configurations as needed. If a stored configuration is selected,
and any feature is changed, the Configuration Name changes to (Untitled). If
you attempt to exit the program without saving the configuration, you will be
prompted to do so.
Defaults
To configure default provisioning, based on the selected Switch Type:
STEP 1
Run the Windows based configuration software.
STEP 2
Select the SWITCH TYPE.
STEP 3
Select
DEFAULTS.
STEP 4
Remove all communications devices from the Simulator and
press the DOWNLOAD button. An automatic RESTART is
issued as part of the
DOWNLOAD.
Important: When the Simulator configuration is changed using the
Windows based configuration software, always reinitialize any
connected devices.
Switch Type
The Simulator is configured at the factory for National ISDN-1 protocol. To
simulate the AT&T 5ESS Custom, ETSI or other future protocols, you must
change the Simulator’s Switch Type.
Switch Type
Emulation
National ISDN-1
NI-1
AT&T Custom
AT&T Custom
DMS100 DMS
Custom
ETSI
NET3
STEP 1
Run the Windows based configuration software.
STEP 2
Select the Switch Type.
STEP 3
Select DEFAULTS (if you want the default settings for the selected
switch)
STEP 3
Remove all communications devices from the Simulator and select
the
DOWNLOAD button. An automatic RESTART is
issued as part of the
DOWNLOAD.
STEP 4
Reconnect all communications devices.